Home▸Energy & Thermodynamics▸Power Plant Cooling Water: Once-Through, Wet Tower and Dry Condenser, Withdrawal, Evaporation and River Heating

Power Plant Cooling Water: Once-Through, Wet Tower and Dry Condenser, Withdrawal, Evaporation and River Heating

Run a coal, gas combined cycle or nuclear plant on a river and choose how its waste heat is rejected. Once-through cooling gives the best efficiency but withdraws a river of water and warms it; a wet cooling tower withdraws a few percent of that but evaporates it; dry air cooling uses no water and loses efficiency on hot days. Set the air temperature, humidity, river temperature and flow, the cooling water rise and the tower cycles of concentration, and read the condenser temperature, efficiency, withdrawal, consumption, blowdown, river warming and dissolved oxygen. Numerical checks cover the plant heat balance, the tower salt balance, the Stull wet-bulb formula and the oxygen saturation table.

Energy & Thermodynamics3DModerate60 FPS📱 Mobile-adapted🟠 Blender💧 Water⇄ 2D version
Power Plant Cooling Water: Once-Through, Wet Tower and Dry Condenser, Withdrawal, Evaporation and River Heating ↗ Open standalone

Thermal power plants — coal, gas, nuclear — reject far more heat than they turn into electricity, and how they get rid of that heat determines how much water they need. This simulator models the three main cooling technologies side by side: once-through river cooling (huge withdrawal, tiny consumption), a wet recirculating tower (small withdrawal, high consumption via evaporation), and a dry air-cooled condenser (almost no water, but a real efficiency penalty on hot days). Adjust plant output and ambient temperature to see the water-energy tradeoff play out in real time.

⚙ Under the hood

Run a coal, gas combined cycle or nuclear plant on a river and choose how its waste heat is rejected. Once-through cooling gives the best efficiency but withdraws a river of water and warms it; a wet cooling tower withdraws a few percent of that but evaporates it; dry air cooling uses no water and loses efficiency on hot days. Set the air temperature, humidity, river temperature and flow, the cooling water rise and the tower cycles of concentration, and read the condenser temperature, efficiency, withdrawal, consumption, blowdown, river warming and dissolved oxygen. Numerical checks cover the plant heat balance, the tower salt balance, the Stull wet-bulb formula and the oxygen saturation table.

water-energy nexuscooling towerthermal power plantdesalinationwater withdrawalenergy efficiencyPower Plant CoolingWater Energy NexusCooling TowerThermal PollutionCondenser

3D · Three.js / WebGL renderer · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)