Stored-Pressure Water Extinguisher: Tank Cutaway, p-V Diagram and Throw Range (2D)
A side view of the throw with droplet trajectories at several moments of the discharge, a cutaway of the tank with its water level and the pressure gauge, and a p-V diagram of the gas with the isothermal and adiabatic reference curves and the work given to the water. Same model and numerical checks as the 3D scene.
A stored-pressure extinguisher pushes water out with the gas above it. The gas expands along p V^n = constant while the water leaves through a nozzle at the Bernoulli speed, so the pressure and the jet weaken as the vessel empties, and the droplets fly with quadratic air drag. Change the charge pressure, vessel size, fill, nozzle diameter and loss coefficient, gas expansion exponent, nozzle angle and height, droplet size and the distance to the fire, and read the jet speed, flow, discharge time, the range against time and how long the jet actually reaches the target. Blender-built extinguisher with six independent numerical checks. Educational physics only; a real fire is for trained people.
A side view of the throw with droplet trajectories at several moments of the discharge, a cutaway of the tank with its water level and the pressure gauge, and a p-V diagram of the gas with the isothermal and adiabatic reference curves and the work given to the water. Same model and numerical checks as the 3D scene.
2D · HTML5 Canvas 2D · 60 FPS target · runs fully client-side, no install