Home▸Energy & Thermodynamics▸Pump Affinity Laws: Pump Curve, System Curve and Power Ledger

Pump Affinity Laws: Pump Curve, System Curve and Power Ledger

Pump curve, system curve and operating points for a throttling valve and a variable-speed drive on the same circuit, with a power-versus-flow chart, a 24-hour demand profile and the loss ledger. Same shared model and numerical checks as the 3D skids.

Energy & Thermodynamics2DModerate60 FPS📱 Mobile-adapted🟠 Blender⇄ 3D version
Pump Affinity Laws: Pump Curve, System Curve and Power Ledger ↗ Open standalone

Industrial pumps, fans and compressors are usually sized for peak demand, but most of the time a process needs less than full flow. This simulator compares the two common ways to deliver less flow: closing a throttling valve while the motor keeps spinning at full speed, or slowing the motor itself with a variable-frequency drive (VFD). Because pump shaft power follows the cube of impeller speed (the affinity laws), the two methods produce very different electricity bills for the exact same reduction in flow. Adjust the target flow rate and switch control methods to watch the 3D pump, live power readout and power-vs-flow chart respond.

⚙ Under the hood

Pump curve, system curve and operating points for a throttling valve and a variable-speed drive on the same circuit, with a power-versus-flow chart, a 24-hour demand profile and the loss ledger. Same shared model and numerical checks as the 3D skids.

Pump Affinity LawsVariable Frequency DriveEnergy EfficiencyOperating Point

2D · HTML5 Canvas 2D · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)