Home▸Geology & Earth Science▸Seismic Lab: Interactive Tuned Mass Damper 3D Simulator

🔬 Seismic Lab: Interactive Tuned Mass Damper 3D Simulator

Explore a realistic 3D earthquake shake-table simulator. Compare skyscraper sway, adjust a tuned mass damper, and learn how vibration control works.

Geology & Earth Science3DModerate60 FPS📱 Mobile-adapted🤖 ChatGPT
Seismic Lab: Interactive Tuned Mass Damper 3D Simulator ↗ Open standalone
02 / UNDERSTAND THE SYSTEM

Engineering the invisible.

What you are seeing, how it works, and why it matters.

About This 3D Simulation

A tall building is not perfectly rigid. When earthquake waves move the ground beneath it, the structure bends and sways because its floors have mass and its structural frame has finite stiffness. Engineers often try to limit that motion with carefully designed combinations of strength, flexibility, energy dissipation, and vibration-control technology. Seismic Lab turns those invisible forces into a clear, hands-on three-dimensional experiment.

The viewer contains two matching seven-storey test towers mounted on synchronized shake tables. The cyan reference tower has no supplemental vibration-control device. The amber tower is fitted with a roof-level tuned mass damper: a heavy moving block connected to the roof by an idealized spring-and-dashpot assembly. Both towers receive exactly the same artificial earthquake input, so any difference in their calculated response comes from the damper rather than a different ground motion.

Zoom in to inspect steel columns, cross-braces, floor decks, glass curtain-wall panels, guide rails, the moving absorber mass, and the shaker machinery below. A live response plot measures the lateral movement of the top floor in each model. Additional instruments show ground acceleration, simulated roof sway, peak motion reduction, and interstorey drift. Every parameter control affects the underlying dynamics: you can change the seismic intensity and frequency, adjust absorber mass, retune its natural frequency, or modify its energy dissipation.

The experiment illustrates a principle used in structural engineering and other branches of mechanical design: a secondary mass can be tuned to reduce motion in a chosen frequency range. Large buildings may use tuned mass dampers to reduce wind-induced motion, and related control technologies are also studied for seismic response. The simulation is not based on a particular landmark and does not claim to reproduce a complete building design.

Use Seismic Lab as an interactive introduction to resonance, mode shapes, forced vibration, damping, and the trade-offs of structural-control design. It is equally useful for curious learners, architecture students, engineering educators, and anyone who wants to see why a building may move dramatically even when the ground movement looks relatively small.

How It Works

From the motion of the base to the reaction of a roof-mounted absorber, this experiment follows a simplified but physically meaningful set of coupled equations.

1. Ground motion becomes structural motion

The shake tables apply the same synthetic horizontal displacement to the base of both structures. The displayed excitation combines two sinusoidal components and a smooth onset. Ground acceleration is computed from that prescribed displacement. Its maximum nominal intensity is selected in units of g, where 1 g is approximately 9.81 m/s². Frequency is measured in hertz, or cycles per second. The input is repeatable for controlled comparison, but it is not a recorded earthquake accelerogram.

2. A seven-degree-of-freedom shear building

Each tower has seven lumped floor masses connected by linear lateral springs and viscous dampers. Let u be the vector of floor displacements relative to the moving ground. The governing relationship is M ü + C u̇ + K u = −M r a_g, where M, C, and K represent mass, damping, and stiffness; r maps horizontal ground acceleration to the floors; and a_g is the ground acceleration. For this model, each floor has mass 215,000 kg and each storey has lateral stiffness 155 MN/m. The selected damping idealization is linear and is not a model of yielding steel.

3. How the tuned mass damper exchanges energy

The protected tower has an eighth dynamic coordinate: the position of the absorber mass relative to the moving ground. A horizontal spring connects it to the roof, producing force F_k = k_d (u_d − u_roof). A dashpot produces F_c = c_d (v_d − v_roof). These forces act with opposite signs on the roof and the moving mass. The absorber’s spring constant is calculated as k_d = m_d (2π f_d)², where f_d equals the tuning ratio multiplied by the estimated first-mode frequency. Its damping coefficient is c_d = 2 ζ_d √(k_d m_d). The controller updates these values whenever you change the relevant sliders.

4. Simulation integration and live measurements

The coupled equations are advanced in small fixed time steps using a semi-implicit Euler integrator, with floor and absorber coordinates tracked in metres. Each rendered floor is displaced horizontally according to its calculated position. Small deflections are visually amplified and large deflections are smoothly compressed so components stay visible; all numeric readings retain their unmodified SI-model values. Live roof sway is the absolute magnitude of top-floor motion relative to the ground. Interstorey drift is the largest displacement difference between successive floors divided by the 3.2 m storey height. The chart compares signed top-floor displacement over recent simulated time, while peak metrics accumulate since Reset.

5. What resonance and tuning reveal

The first-mode frequency is estimated for the ideal uniform shear chain. Excitation near that frequency often produces larger responses than forcing far above or below it. A tuned absorber introduces an additional resonant subsystem, so its effectiveness varies across frequency. Better performance at one frequency does not prove superiority at all frequencies. Increasing damper mass, changing tuning, or adding damping can shift the response peaks. The live reduction percentage is calculated from the two peak roof-sway magnitudes; because the peaks occur at different times and because an absorber can perform poorly when detuned, it can be negative.

6. Scope and limitations

This is a teaching model, not a construction-grade seismic analysis. Its floors are rigid horizontal masses, its frame behavior is linear, and its shaker input is deliberately artificial. The geometry shows a plausible experimental setup but is not used as a finite-element mesh. It does not resolve torsion, material damage, soil interaction, nonlinear isolators, impact limits, or real earthquake records. Those details matter in professional structural design. The model nevertheless demonstrates the physical mechanism behind forced vibration and supplemental damping, and it makes the effect of different parameters observable rather than merely decorative.

GOVERNING PRINCIPLEMü + Ců + Ku = −Mr ag

Relative coordinates, lumped masses, linear springs, viscous dampers, prescribed horizontal base acceleration.

04 / FREQUENTLY ASKED QUESTIONS

Questions, answered.

10 detailed answers about vibration control and the model.

01What is a tuned mass damper in a skyscraper?

A tuned mass damper, or TMD, is an auxiliary moving mass connected to a building through springs, dampers, or a pendulum mechanism. Its natural frequency is deliberately selected to interact with a vibration mode of the structure. When the building sways, the auxiliary mass moves with a different phase and exchanges energy with the structure. Dissipative elements then turn part of that mechanical energy into heat. This demonstration uses a horizontal sliding mass on roof-level guides rather than a real suspended pendulum. You can see the protected tower and an otherwise identical reference tower responding to the same synthetic ground motion, which makes their different behavior easier to compare.

02How does the damper reduce earthquake-induced sway?

An earthquake moves the base of a building, while its floors respond according to their inertia, stiffness, and damping. Near a natural frequency, the motion can grow substantially. A properly tuned secondary mass develops a reaction force that opposes part of the main structure’s motion at the frequencies where the absorber is effective. The dashpot connected to that mass dissipates energy as it moves relative to the roof. In the model, this interaction appears as equal and opposite spring and viscous-damper forces between the roof degree of freedom and the absorber degree of freedom. Reduction is not guaranteed at every excitation frequency, so the live comparison is more informative than a fixed percentage claim.

03What do the seven floors represent in the engineering model?

Each visible floor is treated as a concentrated horizontal mass with one independent lateral displacement. Springs and dashpots between neighboring floors stand in for the combined lateral stiffness and damping of columns, braces, connections, and other structural elements. This is called a shear-building idealization. The floors do not bend or twist, and the model ignores vertical, torsional, and soil–structure interactions. Those omissions make the experiment computationally inexpensive and help isolate the concept of horizontal resonance. The procedural steel frames and glass panels are explanatory geometry: their visual deformation follows the calculated floor positions, but their individual members are not analyzed with a finite-element solver.

04Why does earthquake frequency matter so much?

Every flexible building has natural vibration frequencies determined largely by its mass distribution and lateral stiffness. When ground-motion energy is concentrated near one of those frequencies, a sustained response can be amplified by resonance. Use the Frequency control to sweep across the neighborhood of the first-mode frequency shown in the instrument panel. Both towers may begin moving much more strongly, and the damper’s advantage can become pronounced near its design band. Real earthquakes are transient signals containing many frequencies rather than a perfectly repeating waveform. This simulation intentionally uses a repeatable synthetic two-tone input so changes in the building response are easy to attribute to the chosen control settings.

05What happens if I increase the damper mass?

Increasing the mass ratio makes the auxiliary moving mass heavier compared with the building. With suitable tuning, a heavier mass often gives the absorber more authority to control the dominant motion, potentially widening the useful frequency range. However, performance also depends on the spring stiffness, damping coefficient, and excitation frequency. In a full engineering project, added mass introduces structural loads, space requirements, cost, and practical limits on travel distance. Here the mass slider changes the absorber’s inertial mass and automatically recalculates its spring and damping constants according to the selected frequency ratio and damping ratio. That keeps the demonstration internally consistent while making different designs quick to compare.

06What does tuning ratio mean, and why can it make performance worse?

The tuning ratio is the natural frequency of the auxiliary mass divided by the building’s estimated first-mode frequency. A value near one means the absorber is designed to move in the same general frequency band as the dominant structural mode. The best value depends on the absorber mass ratio, structural damping, and objective of the design, so exactly 1.00 is not universally optimal. Detuning the device may make it less useful at the applied excitation frequency, and a poorly selected absorber can even increase motion over some frequency bands. Try changing Tuning while holding the ground-motion frequency steady; the two displacement traces and peak-response readouts reveal the consequences.

07How is damping different from stiffness and mass?

Mass governs inertia: how strongly an object resists changes in velocity. Stiffness determines the restoring force produced by displacement. Damping represents energy loss, often modeled with a force proportional to relative velocity. These three properties together govern vibration amplitude, phase, and resonant behavior. In the model, a linear spring contributes a force proportional to the displacement difference between the roof and absorber, while a viscous dashpot contributes a force proportional to the velocity difference. Higher absorber damping can limit its travel and broaden the response, but excessive damping can prevent the absorber from moving enough to counteract the building. The best setting is a compromise, not simply the maximum available value.

08How should I run a meaningful experiment with the controls?

Start with the Mild preset and press Play. Observe the two towers for several simulated seconds while the response graph accumulates samples. Increase ground-motion frequency gradually towards the indicated first-mode frequency, keeping the intensity unchanged. Next change only the mass ratio or tuning ratio and compare the moving roof, the amber absorber, and the peak sway measurements. Press Reset before comparing new parameter combinations so residual motion from the previous test does not affect the results. The X-ray option reveals internal structural elements and the absorber mechanism. You can orbit the scene with a pointer, zoom with the wheel, and select components for short explanations.

09Can this simulation predict whether a real building is safe?

No. This is an educational, linear, seven-floor shear-building model driven by artificial base excitation. It does not incorporate measured earthquake records, building-code load combinations, material yielding, cracking, connection failures, foundation dynamics, soil amplification, torsion, vertical shaking, or construction tolerances. It also represents the damper as a simplified sliding mass rather than a manufacturer-specific mechanical assembly. Its live numbers are internally calculated from the stated idealized model, not certified engineering predictions. Real projects require site-specific hazard analysis, calibrated structural models, nonlinear time-history studies when appropriate, and review by qualified structural engineers. Treat this experience as a way to build intuition about vibration control, not as a design or safety tool.

10What advanced idea explains why the damper has a limited effective bandwidth?

A tuned mass damper adds a second resonant subsystem to the structure. Rather than making the original resonance disappear, the coupled system often develops two nearby response peaks separated by a reduction around the tuned frequency. Engineers describe this phenomenon with frequency-response functions and modal coupling. Damping changes the height and width of those peaks, while the absorber mass ratio influences how far apart they sit. Because this demonstration also includes higher building modes and a mixed-frequency input, the visible response is more complex than the textbook two-degree-of-freedom sketch. To explore the idea, vary excitation frequency while keeping the mass and tuning fixed, reset between trials, and watch how the relative benefit changes.

⚙ Under the hood

Explore a realistic 3D earthquake shake-table simulator. Compare skyscraper sway, adjust a tuned mass damper, and learn how vibration control works.

seismictunedmass3D simulationWebGL

3D · Three.js / WebGL renderer · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)