Home▸Geology & Earth Science▸LYSADRON: The Quakewrights Court

🌋 LYSADRON: The Quakewrights Court

LYSADRON — The Quakewright's Court: an interactive 3D Atlantean earthquake engineering laboratory. Test three architecture types against tremors, examine damage and compare seismic designs.

Geology & Earth Science3DModerate60 FPS📱 Mobile-adapted🤖 ChatGPT
LYSADRON: The Quakewrights Court ↗ Open standalone

Field guide & frequently asked questions.

Ten detailed answers for curious visitors, builders and experimenters.

01 How does the earthquake actually move the three monuments? +

The simulation generates a time-varying ground acceleration from a tapered mixture of oscillating signals. This ground motion is applied simultaneously to all three monuments, so they experience the same imposed trial. Each structure is represented by three coupled floor masses connected through horizontal springs and damping elements. The numerical solver updates floor velocities and displacements in small time increments. You see the resulting relative deflections amplified for clarity in the 3D scene. The generated shaking is deterministic for a given trial configuration, which makes comparisons useful. It is not a recorded seismogram, a full geophysical fault-rupture model or a prediction for a real location. Its purpose is to illustrate how different structures respond to the same motion.

02 Why can a comparatively small quake make one roof sway much farther? +

Peak ground acceleration is only one part of the story. The frequency content of shaking and the natural vibration periods of a building strongly affect the response. When an excitation contains energy near a natural frequency, the structure can repeatedly absorb energy and build up a much larger oscillation than expected from the force alone. Mass, stiffness and damping determine those natural frequencies and how quickly vibration dies away. Try reducing intensity while sweeping the dominant wave period across its full range. You may find an especially responsive region for the Columned House. In a real building, the response also depends on multiple modes, nonlinear material behaviour, geometry and site conditions, which this teaching model intentionally simplifies.

03 What separates the Arcaded Court, Columned House and Shielded Bastion? +

The three monuments have different assumed mass and stiffness distributions, as well as different damage thresholds. The Arcaded Court models a relatively substantial, vaulted masonry form whose connected bays spread lateral loads. The Columned House is deliberately more flexible, with narrow supports and open spaces; its lightness does not guarantee a small roof displacement. The Shielded Bastion uses diagonal bracing to increase its lateral resistance, at the cost of a stiffer dynamic response. In the scene, those assumptions appear as distinctive load-bearing details, including arches, slender pillars and diagonal members. These are stylised structural families, not detailed engineering models of historical buildings. Select the monument tiles after a trial to compare roof drift, condition and estimated resonant period.

04 What does the soft-sediment control represent? +

The soft-sediment slider illustrates the idea that geology can alter shaking between the underlying rock and the surface. Certain soil layers may amplify motions or favour lower-frequency vibrations, particularly when their dynamic properties interact with the arriving waves. Here, increasing the setting changes the amplitude and effective period of a synthetic input signal. It does not solve a soil-column wave-propagation equation, account for pore-water pressure, or simulate liquefaction and permanent ground deformation. To explore the concept, compare the Royal Examination with the Drowned Marsh preset, then adjust the same intensity under different sediment settings. For real sites, geotechnical investigations and local design standards are indispensable.

05 Can stronger reinforcement ever produce a surprising result? +

Yes. In this model, reinforcement both increases the stiffness of storey connections and raises the drift threshold at which joint damage begins. Those changes usually improve resistance to excessive relative movement, but increasing stiffness also changes the structure's natural vibration periods. Under some shaking frequencies, the response may shift towards rather than away from resonance. A very stiff structure can also experience substantial forces while displaying a relatively small displacement. That is why a serious structural assessment never relies on one indicator or one simple notion of strength. Try keeping the wave period fixed while changing reinforcement in controlled steps and comparing the displacement traces. The simulator's damage values remain heuristic, not verified stress-capacity calculations.

06 How does the bronze tuned counterweight reduce vibration? +

The counterweight is an additional mass that moves relative to a building's upper floor. A spring and damper connect it to that floor, allowing the secondary mass to exchange energy and exert a reaction force. If its tuning suits the excitation and structural dynamics, this action can reduce the roof's motion. Its visible movement deliberately lags or opposes the roof under many conditions. However, a tuned-mass damper is not a universal shield: its benefit depends on mass ratio, tuning, damping and the frequencies being excited. The device is a real modern engineering concept, while the elaborate Atlantean bronze version is an invention. Toggle it between otherwise identical trials to compare the roof traces fairly.

07 Why do the joint-damage percentages change during a trial? +

Each numerical step checks the relative sideward displacement between adjacent floors, often called interstorey drift. When a drift exceeds a chosen illustrative tolerance, the model adds damage to the affected joint layer. Stronger, repeated excursions accumulate damage faster. The effective stiffness of heavily damaged storeys then reduces, producing a feedback between deformation and subsequent movement. This is intended to teach that structural condition can change during a sequence of shocks; it is not a microscopic fracture simulation. An actual assessment would require calibrated material laws, member details, construction quality, ground conditions and often sophisticated numerical analysis. The displayed percentage should therefore be interpreted as an educational condition index, not a physical probability of collapse.

08 Can I pause, restart, inspect objects and use the simulation on a phone? +

Yes. Release the Tremor starts a new event; Pause freezes the state, and Resume continues it. Reset restores the initial positions, clears accumulated damage and empties the chart. The camera responds to dragging, and a Shift-drag pans rather than rotates; the mouse wheel zooms. On touch screens, drag with one finger to orbit and pinch with two fingers to zoom or pan. Three camera buttons provide gallery, elevation and overhead views, with a fourth returning the original composition. Select any monument using its tile or click its position in the scene. All seven numeric controls and the counterweight switch affect the actual model. Mobile layouts move the engineering console beneath the 3D viewport for comfortable access.

09 Which scenarios should I compare first, and what makes a fair experiment? +

Begin with the Royal Examination as a baseline, then use the Sundered Fault to observe a more forceful pulse. The Drowned Marsh emphasises sediment amplification, and Aftershock Sequence provides a longer event with repeated loading. For a fair controlled comparison, reset before every run, keep all settings unchanged except the one you intend to test, and compare the same monument's maximum drift and final damage. The live chart offers additional context, because two trials can share a peak displacement while behaving very differently over time. For example, modify damping in one pair of trials and roof load in another. Recording the settings alongside the results makes the experience more like a small reproducible laboratory exercise.

10 Is this evidence of Atlantean technology or a tool for real building design? +

Neither. Atlantis is known primarily from Plato's dialogues, and no verified archaeological evidence establishes this specific civilisation, laboratory or its fictional machines. LYSADRON deliberately combines imaginative worldbuilding with selected ideas from structural dynamics. Its three-storey spring-and-mass representation demonstrates inertia, resonance, damping and relative displacement, but it omits many indispensable engineering phenomena: three-dimensional torsion, nonlinear member forces, joint detailing, foundation failure, vertical shaking and collapse mechanics among them. It must never be used to determine whether an actual structure is safe, or in place of qualified engineering advice and applicable codes. Its educational value lies in helping visitors ask informed questions about how buildings and the moving ground interact.

⚙ Under the hood

LYSADRON — The Quakewright's Court: an interactive 3D Atlantean earthquake engineering laboratory. Test three architecture types against tremors, examine...

3D simulationAtlantisinteractive science

3D · Three.js / WebGL renderer · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)