🌍 KYTHERION: The Tectonic Loom Simulator
KYTHERION — The Tectonic Loom. An interactive speculative Atlantean earthquake engineering museum with a real-time coupled oscillator simulator and procedural 3D city.
Frequently asked questions.
01 What exactly is being simulated when the three towers sway?+
Each tower is represented by a lateral mass–spring–damper oscillator driven by the same artificial ground-acceleration signal. The equations solve for motion relative to the foundation, which is why identical shaking can result in different displacements for the three buildings. The model assigns different natural frequencies to the Needle, Archive and Observatory to make differences in structural response visible. Optional skybridge forces couple their movement, and optional suspended counterweights add one more moving coordinate to each tower. The visual models stretch their upper floors in proportion to the solved displacement. This is a deliberately reduced engineering model: it does not simulate every column, masonry joint or three-dimensional earthquake wave.
02 How do tuned mass dampers reduce motion, and can they make it worse?+
A tuned mass damper is a secondary moving body connected to a larger structure through stiffness and dissipation. When its natural frequency is close to the dominant motion of the building, the smaller mass may move out of phase and draw energy away from the main oscillation. In Kytherion, the metallic weights suspended beneath the crowns correspond to those secondary coordinates. The Counterweight Mass slider changes the effective mass ratio, while Tuning Ratio changes their preferred frequency. The effect depends on the forcing signal and timing: a poorly tuned, inadequately damped or badly timed counterweight can provide little benefit and can sometimes increase selected response peaks. Compare entire runs before judging success.
03 Why does changing earthquake frequency affect the towers so much?+
Every elastic oscillator has one or more natural frequencies at which it prefers to move. If an earthquake contains substantial energy near one of those frequencies, repeated forcing can reinforce the response and produce resonance. Kytherion deliberately gives the three structures different baseline frequencies, so a frequency that excites one tower strongly may affect another less. Stiffness changes shift those frequencies; coupling can create collective modes rather than three independent resonances. The Harmonic Trial is the clearest protocol for testing this relationship because it sustains a comparatively regular signal. Real earthquakes contain broad and changing frequency content, and real building periods can change as damage accumulates; this simplified model does not capture all those complexities.
04 How should I run a fair before-and-after engineering experiment?+
Choose one protocol, leave the starting settings unchanged and press Restart so that the simulation begins at time zero. Let the event finish while monitoring the peak structural drift shown on the right, and note the selected tower's maximum offset if that is your measurement of interest. Change just one parameter—such as engaging the suspended masses—then press Restart and run the same protocol again. Because the synthetic wave signal is deterministic for a given protocol, meaningful differences come from the model settings. Be careful not to inject an extra aftershock during one run but not the other. Repeat a few times, compare individual towers as well as the aggregate peak, and resist drawing universal conclusions from one scenario.
05 What are the differences between the four earthquake protocols?+
Stillwater Calibration applies a small, gently varying forcing that is useful for learning the basic controls and viewing natural oscillations. The Harmonic Trial supplies sustained narrow-band shaking, which helps reveal resonance when you tune frequency or stiffness. South Fault Rupture combines a strong early impulse with subsequent decaying waves, giving a more transient response and a clear first peak. Twin Aftershocks applies two distinct bursts; the second can arrive while the towers are still moving. Choosing a protocol also resets the clock and selects a sensible set of initial controls, after which every slider remains editable. None of the waveforms reproduces a measured earthquake or a specific real-world fault.
06 Can I manipulate the camera and examine an individual tower closely?+
Yes. Drag inside the main viewport with a mouse or single finger to orbit the camera around the exhibit. Shift-drag with a mouse, or use a two-finger gesture on touchscreens, to pan the target point. Scroll or pinch to change distance. Plan changes to a near-overhead view, Section moves closer to the lantern-chamber height, and Reset View restores the original overview. Click a tower directly, or press one of the three numbered inspector buttons to select it. The inspector then reports that tower's live offset, peak offset, nominal natural frequency and illustrative integrity index. Press Focus Selected Structure to move the view towards that tower; you can continue orbiting afterwards.
07 What does the integrity percentage mean, and is it a safety verdict?+
The integrity index is an illustrative health score derived from how often and how far simulated structural drift exceeds the selected clearance. It adds a small cumulative penalty during excessive displacement, making it useful for comparing the consequences of different parameter settings. The risk label also reports when a current or historical displacement approaches the nominal drift clearance. Neither measurement uses real material strength tests, code-defined drift ratios, reinforced-concrete detailing, soil conditions or calibrated fragility curves. It should not be interpreted as a probability of collapse or evidence that a physical building is safe. For actual structural safety decisions, qualified engineers use appropriate design standards, measured properties and validated analysis tools.
08 Is the Atlantean engineering historically documented?+
No. Kytherion, its three towers, the South Escarpment precinct, the seismic school and its bronze suspended counterweights are fictional creations for this exhibit. Atlantis is known primarily through Plato's ancient philosophical dialogues, and there is no accepted archaeological evidence for the particular technology or city presented here. The simulation borrows genuine concepts from dynamics and earthquake engineering but places them within a mythological artistic setting to invite curiosity. It is best understood as speculative historical fiction with an educational physics engine, not as a digitally restored ruin or a claim about lost ancient technology. Its imaginary catalogue number and date support the museum aesthetic rather than historical authentication.
09 Why can stronger skybridge coupling help one structure but hurt another?+
Connecting oscillators means that movement of one can exert a force on another. In Kytherion, the coupling slider represents elastic exchange between neighbouring towers; it is not a literal material-strength model of the visible skybridges. If one tower would otherwise move a long way, a connection may allow a stiffer neighbour to restrain it. Yet this force does not disappear: the connected neighbour can inherit additional motion and new collective resonance frequencies can appear. The outcome depends on the towers' stiffnesses, dampers and the earthquake's frequency content. Study each seismograph trace separately while raising the slider. The best setting for the maximum of all three responses might differ from the best setting for any one tower.
10 Can this application run offline, and what are its technical limits?+
The project includes local HTML, CSS and JavaScript files and requires no account, service, external imagery, 3D model download or paid API. Open index.html in a modern browser; its primary scene needs WebGL2, with a simpler Canvas 2D engineering diagram if WebGL2 is unavailable. The engine advances its reduced equations in small numerical steps and samples a rolling displacement chart, but it is not intended for large-scale finite-element analysis. Browser performance, power-saving modes and extreme manual inputs can influence the smoothness of the rendering. Camera state, parameter values and simulation history are held locally during the current session; Restart returns the selected experiment to its beginning without contacting a server.
KYTHERION — The Tectonic Loom. An interactive speculative Atlantean earthquake engineering museum with a real-time coupled oscillator simulator and...
3D · Three.js / WebGL renderer · 60 FPS target · runs fully client-side, no install