Home▸Frozen Shoulder (Adhesive Capsulitis)▸Range of Motion Loss Measurement Simulator

🥶 Range of Motion Loss Measurement Simulator

Interactive goniometer for measuring loss of active and passive range of motion, external rotation of the shoulder during adhesive capsulitis.

Frozen Shoulder (Adhesive Capsulitis)2DModerate60 FPS
shoulder-range-of-motion-loss-simulator ↗ Open standalone

Normal Shoulder Range of Motion

A healthy capsule allows full, symmetric, pain-free shoulder movement.

  • 180°: Active abduction (Full overhead reach without pain.)
  • 180°: Passive abduction (Examiner-assisted motion matches active motion.)
  • 90°: External rotation (Full outward rotation with elbow at side.)
  • 0%: Capsular pattern match (No restriction pattern is detected yet.)

What a goniometer measures

A goniometer tracks the angle between two moving body segments.

Active versus passive testing

Active motion relies on patient effort; passive motion uses examiner force.

A gap between active and passive readings often signals pain, not stiffness.

Why a baseline matters

Baseline angles give clinicians a reference for tracking future stiffness.

Mild Restriction — Early Adhesive Capsulitis

Synovial inflammation starts narrowing the shoulder's outer range.

  • 153°: Active abduction (Overhead reach begins to feel guarded.)
  • 172°: Passive abduction (Passive range still greatly exceeds active range.)
  • 72°: External rotation (Outward rotation is mildly but noticeably reduced.)
  • 30%: Capsular pattern match (Pattern is only beginning to take shape.)

Synovitis phase begins

Inflamed synovium thickens and irritates the joint capsule lining.

Pain-guarded active motion

Patients stop short of full range to avoid a sharp pinch.

A widening active-passive gap

Passive range still nearly matches normal, unlike true stiffness.

Moderate Restriction — Capsule Thickening

Fibrotic thickening now blocks both active and passive motion.

  • 108°: Active abduction (Reaching shoulder height becomes clearly difficult.)
  • 137°: Passive abduction (Examiner assistance yields noticeably less bonus range.)
  • 50°: External rotation (Rotation loss now outpaces the abduction loss.)
  • 60%: Capsular pattern match (The classic capsular restriction ratio is emerging.)

Fibrosis replaces inflammation

Collagen deposits stiffen the capsule around the humeral head.

External rotation drops fastest

The anterior capsule contracts first, limiting rotation most severely.

Passive range starts converging

The gap between active and passive readings keeps shrinking.

Severe Restriction — True Capsular End-Feel

Passive range is now restricted almost as much as active range.

  • 63°: Active abduction (Overhead reach is largely lost to stiffness.)
  • 81°: Passive abduction (Examiner force adds only a small residual arc.)
  • 27°: External rotation (Rotation is severely capped by the tight capsule.)
  • 85%: Capsular pattern match (The hallmark capsular end-feel is now unmistakable.)

A hard, capsular end-feel

The joint stops abruptly, not softly, at its restricted limit.

Active no longer explains it

Pain alone cannot explain a passive range this limited.

Functional impact grows

Reaching overhead or behind the back becomes very difficult.

Goniometer Measurement Complete

Final readings confirm the classic frozen-shoulder capsular pattern.

  • 63°: Active abduction (Recorded angle matches the prior clinic visit.)
  • 69°: Passive abduction (Passive range has nearly converged with active range.)
  • 27°: External rotation (Most-restricted motion, as capsular pattern predicts.)
  • 95%: Capsular pattern match (Measurement confirms the diagnosis with high confidence.)

Reading the capsular pattern

External rotation loss exceeds abduction loss in classic frozen shoulder.

Documenting for the chart

Both active and passive angles are recorded at every visit.

Guiding the treatment plan

Confirmed angles steer physical therapy and injection decisions.

Serial goniometer readings are the simplest way to track recovery over months.
⚙ Under the hood

Interactive goniometer for measuring loss of active and passive range of motion, external rotation of the shoulder during adhesive capsulitis.

CanvasBiomedicine

2D · HTML5 Canvas 2D · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)