Home▸Fitzpatrick Phototype & NB-UVB Dosing▸NB-UVB Phototherapy Starting Dose Calculator Simulator

☀️ NB-UVB Phototherapy Starting Dose Calculator Simulator

Calculates the starting dose of narrow-band UVB phototherapy based on the skin phototype.

Fitzpatrick Phototype & NB-UVB Dosing2DModerate60 FPS
nbuvb-starting-dose-calculator-simulator ↗ Open standalone

Starting Dose by Fitzpatrick Phototype

Baseline NB-UVB dose scales with skin phototype.

  • I–VI: Phototypes (Fitzpatrick scale)
  • ~100 mJ: Type I dose (lowest starting dose)
  • ~300 mJ: Type VI dose (highest starting dose)
  • ~20%: Increment step (per visit, typical)

Phototype lookup

Darker phototypes tolerate higher initial UV-B doses.

Always confirm phototype by patient history, not visual estimate alone.

Minimal Erythema Dose Reference Chart

MED anchors the starting dose calculation per patient.

  • Lowest UV: MED definition (dose causing erythema)
  • ~200 mJ/cm²: Type I MED (reference chart value)
  • ~600 mJ/cm²: Type VI MED (reference chart value)
  • Phototest: Test method (or phototype estimate)

MED chart use

Chart-based MED is used when phototesting is unavailable.

Measured MED is preferred over chart estimates when feasible.

Percentage-of-MED Starting Protocol

Standard protocols start at 50% of estimated MED.

  • 50%: Standard start (of estimated MED)
  • 25–30%: Conservative start (for sensitive patients)
  • 10–20%: Increase per visit (if no erythema)
  • ~40 mJ: Max increase cap (per session, typical)

Percent-based dosing

Dose escalation follows tolerance and erythema response.

Reduce percentage if prior erythema or missed sessions occurred.

Body Site Sensitivity Adjustment

Sensitive body sites require lower starting doses.

  • Face, neck: High-sensitivity sites (and flexural areas)
  • ~30%: Reduction factor (typical dose reduction)
  • Trunk, limbs: Standard sites (full calculated dose)
  • Genitalia: Shielding advised (routinely shielded)

Site-specific dosing

Adjust dose downward for thin or sensitive skin regions.

Sensitive-site burns are a leading cause of treatment interruption.

Initial Dose Confirmation

Final adjusted dose is confirmed before first exposure.

  • Phototype +: Final check (site adjustment combined)
  • Chart entry: Documentation (recorded per session)
  • Each visit: Review interval (reassess tolerance)
  • Built-in: Safety margin (below erythema threshold)

Confirmed starting dose

Adjusted dose is logged and used for session one.

Confirm no photosensitizing medications before starting treatment.
⚙ Under the hood

Calculates the starting dose of narrow-band UVB phototherapy based on the skin phototype.

CanvasBiomedicine

2D · HTML5 Canvas 2D · 60 FPS target · runs fully client-side, no install

What did you find?

Add reproduction steps (optional)