Aerial Wildfire Containment: Wind-Driven Fire Growth and Retardant Lines

A wildfire grows as a wind-stretched ellipse. Drop retardant lines from an air tanker and see how much land you save.

Switch to 2D

Presets

Playback

Parameters

Camera

Layers

Quality

Model check

The science

Spread of a fire. Without wind a fire grows as a circle at the no-wind spread rate b (metres per minute). With wind it grows as an ellipse with the ignition point at its rear focus (Huygens principle, Richards 1990): ROS(θ) = b / (LB (1 - e cosθ)), where θ is the angle from the wind direction, e = √(1 - 1/LB²) and the length-to-breadth ratio LB comes from Anderson (1983): LB = 0.936 e0.2566 U + 0.461 e-0.1548 U - 0.397 with U the mid-flame wind in miles per hour, capped at 8. Head, flank and back rates therefore differ by factors of about LB.

Fuel and moisture. The no-wind rate is R0 (grass 4, shrub 2.2, timber 0.9 m/min, illustrative round numbers) times Rothermel's moisture damping coefficient ηM = 1 - 2.59 r + 5.11 r² - 3.52 r³, with r = moisture / moisture of extinction. Water and bare ground cannot burn.

Solving it on a map. Each 30 m cell gets a spread rate. Arrival times are found with Dijkstra's algorithm on a 32-direction graph; the time to cross an edge is the integral of 1/ROS along it. When you drop retardant or change the wind the solver keeps everything already burning and recomputes the rest.

Retardant. A tanker load V laid at coverage C (litres per square metre) covers V / (C × 48 m) metres of a 48 m wide line. Cells whose coverage is at least the requirement for their fuel (0.5, 1.0, 1.5 L/m² for grass, shrub, timber; illustrative values after the US coverage-level idea) cannot burn; lower coverage only slows the fire by 1 - C/Creq. The ends of a line are tapered.

Checks. The solver is compared with a circle (no wind), with the ellipse length-to-breadth ratio and area, with the head-fire distance rate on the wind axis, with a closed retardant ring (nothing outside may burn), and with the exact delay a partly effective strip should cause.

Simplifications. Flat ground, uniform fuel inside a cell, one fuel layer, steady wind at mid-flame height, no slope, no ember spotting, no crown fire, no fire-induced wind, no diurnal weather, retardant that never washes out, and a spread rate that does not depend on fuel load. The aircraft and trees are drawn larger than their scale. This is an educational model, not a tool for planning real fire suppression.

Loading model...
Loading Blender model...
Burnt area against time, with and without drops
Grass spread rate against angle from the wind
Length : breadth against wind speed
Made with 🟠 Blender · Three.js