Presets
Playback
Parameters
Camera
Layers
Quality
Model check
The science
What is modelled
A small pool-type research reactor: 33 fuel rods and four control rods stand on a grid plate in a tiled water pool under a bridge with drive motors. The page solves the neutron chain reaction in real time with six delayed-neutron groups, an S-shaped control rod worth curve and two temperature feedbacks (fuel and coolant), so you can see why a reactor is controllable: most neutrons of a chain reaction come from the fission itself within microseconds, but a small delayed fraction arrives seconds later and sets the pace. The hall, pool, fuel and rods are Blender-built models; the blue glow and the neutron cloud scale with the simulated power.
Equations
- Point kinetics:
dn/dt = [(ρ − β)/Λ] n + Σ λi Ci + S,dCi/dt = (βi/Λ) n − λi Ci, with Λ the prompt neutron generation time, β = Σ βi (0.65 % for U-235) and k = 1/(1 − ρ). - Reactivity:
ρ = ρrods(x) + αD (Tfuel − T0) + αM (Tcool − T0) + ρstep; the rod worth follows an S-shaped integral curve(1 − cos πx)/2of the insertion x. - Stable period: the roots of the inhour equation
ρ = Λ ω + Σ βi ω / (ω + λi). At ρ ≥ β the reactor is prompt critical and the power grows on the microsecond-to-millisecond scale of Λ alone. - Heat:
Cf dTf/dt = P − h (Tf − Tc),Cc dTc/dt = h (Tf − Tc) − hc (Tc − Tpool), with P = n P0. Negative coefficients make the power settle by itself.
Checks run in the page
- A positive reactivity step: the simulated stable period against the largest root of the inhour equation.
- A shutdown step: the slow decay against the matching negative inhour root.
- Feedback equilibrium: the steady power with rods held +60 pcm out of critical against the analytic
P = −ρext / ((αD + αM)/hc + αD/h)(heat capacities are scaled down only to reach equilibrium sooner).
Honest simplifications
This is zero-dimensional point kinetics: no spatial flux shape, no xenon, no burnup, a single lumped fuel and coolant temperature, and no decay heat after shutdown. Parameters are illustrative values in the range of small research reactors, not a model of any real plant. Automatic trips (120 % power, 650 C fuel, 3 s period) are a simplified safety system; with them switched off the model shows how a large reactivity step behaves, but it has no fuel damage model. It is a physics lesson on the neutron balance, not an operating guide.
What to try
- Lower the rod insertion by one percent: the power rises on a period of tens of seconds, then feedback stops it.
- Press Insert reactivity step with +200 pcm, then with a value above beta (650 pcm for U-235) and trips off: the second case jumps almost at once.
- Choose Weak delayed neutrons (Pu-239-like): the same step is much harder to control.
- Press SCRAM and watch the prompt drop followed by the slow decay on the graph.