The synthetic response follows x(t) = x∞ + (x0 − x∞)e−t/τ. A deterministic noise sequence is added to the model response. A log-spaced grid search estimates τ by minimizing the root-mean-square residual.
The report compares the fitted time constant with the hydraulic response scale τhyd ≈ SyL²/(Kb). The data are synthetic and intended for model-fitting practice, not evidence from a real aquifer.
Simplifications: first-order toe response, fixed pre/post pumping states, independent Gaussian-like noise and known asymptote. No parameter uncertainty intervals are inferred.
Independent numerical check: α × (ρs − ρf) = 40 × 25 = 1000 kg/m³ = ρf.