Tabless Cell Current Path (2D)

Where does the current run inside a wound cell, and where does the heat end up? Single tab, multi tab and tabless compared.

Switch to 3D

Presets

Playback

Cell diameter

Current collection

Cooling

Design

Time

Model checks

The science

Why tabs matter

A wound cell carries current in a metal foil that can be 2 to 4 metres long but only about 6 cm wide. With a single tab the current of the whole electrode must run along the foil to reach it: the foil resistance of a strip collected at one end is R = Rs L/(3W) (the factor 3 is the usual distributed-load average), and the Joule heat concentrates near the tab. Many tabs divide the path, R = Rs L/(12 W N²) for N evenly spread tabs, and a tabless cell welds the whole foil edge to a plate so the current only crosses the foil width: R = Rs W/(3L). The model solves the foil as a discretised resistor sheet with a banded Cholesky nodal solve (the map at the top) and checks the two ideal cases against these closed forms.

From foil heat to temperature

The foil heating, the area-specific ionic resistance (which falls as the cell warms, Arrhenius) and the weld or plate resistance become volumetric heat sources in an axisymmetric (r, z) conduction problem with strongly anisotropic conductivity (about 1 W/m/K radially, 30 W/m/K along the axis, typical of a jelly roll), cooled through the can wall and/or base plate. The top view maps radius back to position along the unrolled foil through the spiral relation x(r) = π(r² − r0²)/tturn. Playback shows the transient (implicit time stepping) approaching the steady state shown in the graphs.

Honest simplifications: constants such as the area-specific resistance (13 ohm cm²), turn thickness, areal capacity and heat-transfer coefficients are illustrative; resistance and thermal conductivity are constant; no entropic heat, no state-of-charge dependence, no internal short or runaway; the foil current is injected uniformly (a constant current density); and results above about 150 C are shown only to illustrate how bad a single tab becomes - the model is not valid there. Not a battery design tool. The 2D view shares its physics module with the 3D lab.

What to try
  • 46 mm, ONE tab, 1C then TABLESS: the foil resistance falls by about four orders of magnitude and the hot spot disappears (compare the resistance chart).
  • 5C: base plate versus wall + base: the axial conduction is 30 times better than radial, so cooling the base reaches the core.
  • Move the tab count slider on a multi-tab cell and watch the foil heat map redistribute.
  • Thin 5 um foil: higher sheet resistance, more foil heat in the tabbed designs.
Temperature during the discharge
Steady-state profiles: radial and axial
Steady hottest point against discharge rate
Resistance breakdown by cell type