BINARY SEPARATION · 05 / 08
OFFLINE · IDEAL BINARY VLEThermodynamic model explorer
Inspect Antoine vapour pressures, Raoult’s law, bubble-point temperature, equilibrium vapour composition and relative volatility.
THERMODYNAMIC CALCULATOR
ANTOINE + RAOULTSingle-state equilibrium explorer
Choose a liquid composition and inspect saturation pressures and the equilibrium vapour.
Calculated state
What the engine solves
log₁₀(Pᵢˢᵃᵗ / mmHg) = Aᵢ − Bᵢ / (T / °C + Cᵢ)
P = xA·PAˢᵃᵗ + (1 − xA)·PBˢᵃᵗ
yA = xA·PAˢᵃᵗ / P
The bubble-point temperature is found by bisection. The ideal-liquid assumption sets both activity coefficients to one.