Charge separation in a thundercloud: tripole field, breakdown threshold, stepped leaders and thunder delay.
running...
The science
Ice-graupel collisions in a strong updraft separate charge: graupel falls with negative charge, small ice crystals carry positive charge upward. The model uses a tripole of point charges: +Q at 9 km, −Q at 6 km, a small lower +0.1Q at 3 km, charged at a constant current I (A) (dQ/dt = I).
Midway between the main layers the field is E = 8kQ/d² (k = 8.99×10&sup9; N m²/C², d = 3 km). A flash starts when E exceeds an effective breakdown threshold Eb = 200 kV/m (well below air's 3 MV/m because of runaway-electron and ice-crystal effects), so Qb = Eb d² / 8k. Each flash neutralises 40-70% of Q. Energy is W ≈ ½ ΔQ · V with V = Eb d, giving gigajoule-scale flashes as observed.
The ground field at the observer includes the image charges: Eg = 2 Σ kQi hi / (hi² + r²)3/2. Thunder delay is the slant distance divided by the speed of sound 343 m/s (light delay neglected): about 3 s per km.
The bolt path is a stepped-leader random walk with a downward bias and branching; it is a visual model, not a computed streamer solution (a true model needs the dielectric-breakdown equation). Simplifications: point charges instead of extended regions, constant breakdown threshold, no corona, no multiple return strokes physics. Cloud-to-ground leaders head for the ground; the rest are intra-cloud between the layers.