Dew Point Lab

2D companion of the dew-point lab: dew on a cold glass and fog on a cold night are the same crossing of the dew point.

Switch to 3D

Presets

Playback

Apparatus

Model checks

The science

What is modelled

The dew point is the temperature at which the air you have would be exactly saturated. A glass whose wall is colder than that collects water from the air; air that cools below it at night leaves the excess as fog droplets, which scatter light and cut the visibility.

Equations

  • Saturation pressure (Magnus) es(T) = 611.2 Pa · exp(17.62 T / (243.12 + T)).
  • Dew point Td = 243.12 γ / (17.62 − γ), γ = ln(RH/100) + 17.62 T / (243.12 + T).
  • Glass wall Ts(t) = Tw + (T − Tw) e−t/τ; film growth dm/dt = k (eair − es(Ts)) / (Rv T) when positive.
  • Fog liquid water LWC = (e0 − es(T)) / (Rv T) with the vapour pressure e0 fixed, extinction β = 3 LWC / (2 ρw r), visibility 3.912 / β.

Checks run in the page

  • Magnus agrees with the independent Buck saturation curve.
  • Magnus agrees with the Clausius-Clapeyron inversion.
  • The glass onset time equals the analytic crossing time.
  • The fog onset equals the time to cool to the dew point.

Honest simplifications

The vapour pressure of the night air is held at its evening value, the droplets all have one size, nothing settles out and the glass film never evaporates or runs. The numbers show the trends and the ordering of events, not a forecast.

What to try
  • Press Dry winter room: the dew point sits below the ice-water temperature and no dew forms.
  • Press Barely cool glass and find the water temperature at which dew just stops.
  • Press Clear cold night and watch the houses vanish as the air passes its dew point.
Dew point against humidity
Glass wall temperature against time
Water film on the glass
Night visibility