Charging a pack follows a constant-current then constant-voltage curve: the cells accept a current limited by their C-rate until the pack voltage reaches its ceiling, after which the current must taper. The pack open-circuit voltage and internal resistance depend on state of charge and temperature, and the pack heats by I²R, so cold packs charge more slowly and hot packs are derated. The upper plot shows power and pack temperature against state of charge (time-stepped from the shared model).
The queue plot treats the station as an M/M/c queue: Poisson arrivals at rate lambda, c stalls, mean service time = charge time + 80 s of plugging in and out. Erlang C gives the probability of waiting and the mean wait Wq = C(c,a) / (c mu - lambda) with offered load a = lambda/mu. Unstable queues (lambda ≥ c mu) are shown as off-scale.
Checks: the time-stepped charge time must match the closed form (CC linear plus Simpson integral of the CV stage), and Erlang C must match an independent event simulation. Simplifications: a single car at a time, no shared-cabinet power split here (the 3D page has it), constant ambient temperature. The topic is educational and not affiliated with any charging network or vehicle maker.