DESIGN A · BASELINE
Reference pore structure; shared values are controlled above.
Compare a baseline wick with a higher-permeability alternative. Both designs see exactly the same heat input and condenser inclination.
Water properties are held at their 60 °C reference values; geometry and operating conditions are illustrative.
Reference pore structure; shared values are controlled above.
Coarser pores, higher permeability and a larger flow area.
A larger pore raises capillary pressure less effectively because ΔPcap varies inversely with pore radius. Higher permeability and wick area reduce liquid friction, but may require a different pore structure in real materials.
The comparison uses the same reduced-order pressure balance for both designs. Design B is a fixed illustrative alternative: pore radius 18 µm, permeability 3.0 × 10⁻¹⁰ m², wick area 125 mm² and vapour radius 4 mm. The baseline is controlled by the sliders.
Assumptions: steady one-dimensional transport; uniform saturated water properties at 60 °C; cylindrical laminar vapour core; Darcy flow through a homogeneous wick; constant effective length; no sonic, boiling, entrainment or viscous limit. Positive inclination places the condenser above the evaporator. Values are illustrative, not a design certification.
Independent numerical check: the displayed energy-closure readout reconstructs heat rate from ṁ × hfg and compares it with the entered heat load.