Warm water in the collector is less dense. It rises to the elevated tank while cooler water returns to the collector.
Measure the circulation
Pause after the flow settles, then compare the live flow with the steady Darcy–Weisbach prediction for the current temperature difference and pipe geometry.
Independent numerical checks
The scienceGoverning equations, assumptions and limits+
1 · Buoyancy drives the loop
Water density changes with temperature. With the tank above the collector, the pressure head is approximated by
If the collector is hotter, it is less dense and the head drives the daytime circulation. If it becomes colder than the tank, the sign changes and an unprotected loop can reverse.
2 · Pipe resistance sets the flow
The loop flow has hydraulic inertia and loses pressure through wall friction and fittings:
The Darcy friction factor uses 64/Re in laminar flow and the Swamee–Jain approximation in turbulent flow. A check valve is idealised as a perfect one-way gate.
3 · Heat moves with the water
The collector and tank are treated as two well-mixed thermal masses:
Here ṁ uses the magnitude of loop flow. A negative heat-transfer rate means the tank is losing heat to the colder collector.
What is simplified?
- Textbook constants: g = 9.80665 m/s² and cp = 4182 J/(kg·K).
- Illustrative parameters: collector efficiency, heat-loss coefficients, pipe length, fitting losses and thermal capacities.
- Illustrative model: one collector node and one fully mixed tank; no vertical stratification, pipe heat storage, pump, phase change, boiling, freezing or valve leakage.
- Water properties: empirical density and viscosity correlations over the liquid-water range; the displayed temperatures are kept below 100 °C.
- Not a design tool: real systems need correctly sized components, pressure protection and freeze protection.