PASSIVE SOLAR HEATING · FLOW REVERSAL

When Solar Collectors Run Backwards at Night

A thermosiphon needs no pump. But when the collector becomes colder than the tank, the same buoyancy that moved heat uphill by day can quietly send it back downhill after sunset.

01FOLLOW THE
HEAT
LIVE SYSTEM VIEWNOT TO SCALE · ILLUSTRATIVE
DAYTIME CIRCULATIONSCALED SIM TIME · 00:00

Warm water in the collector is less dense. It rises to the elevated tank while cooler water returns to the collector.

LOOP FLOW RATE i
+0.00 L/min
collector → tank
BUOYANCY HEAD i
+0.0 Pa
g × height × density difference
COLLECTOR WATER i
66.0 °C
solar absorber + fluid
STORAGE TANK i
35.0 °C
stored thermal energy
HEAT TRANSFER TO TANK i
+0 W
positive = heat delivered to storage
FIELD EXPERIMENT 01

Measure the circulation

Pause after the flow settles, then compare the live flow with the steady Darcy–Weisbach prediction for the current temperature difference and pipe geometry.

Waiting for a measurement
THEORY · HYDROSTATIC HEAD = PIPE FRICTION + MINOR LOSSES
MODEL INTEGRITY · TEXTBOOK / NUMERICAL REFERENCES

Independent numerical checks

✓
Hydrostatic head identity32-slice column sum vs. gHΔρ
0.000%
✓
Laminar pipe-loss lawDarcy friction vs. Hagen–Poiseuille
0.000%
✓
Water-density referenceCorrelation vs. textbook table
0.000%
✓
Thermal energy ledgerStored energy vs. net heat input
0.000%
CHECK VALUES ARE LIVE · DIFFERENCES SHOWN AS PERCENT
∑The scienceGoverning equations, assumptions and limits+

1 · Buoyancy drives the loop

Water density changes with temperature. With the tank above the collector, the pressure head is approximated by

Δpb = g H [ρ(Ttank) − ρ(Tcollector)]

If the collector is hotter, it is less dense and the head drives the daytime circulation. If it becomes colder than the tank, the sign changes and an unprotected loop can reverse.

2 · Pipe resistance sets the flow

The loop flow has hydraulic inertia and loses pressure through wall friction and fittings:

dQ/dt = Ap(Δpb − Δploss)/(ρ L)
Δploss = ½ρ(fL/D + K)v|v|

The Darcy friction factor uses 64/Re in laminar flow and the Swamee–Jain approximation in turbulent flow. A check valve is idealised as a perfect one-way gate.

3 · Heat moves with the water

The collector and tank are treated as two well-mixed thermal masses:

CcdTc/dt = ηAG − UcA(Tc−Ta) − ṁcp(Tc−Tt)
CtdTt/dt = ṁcp(Tc−Tt) − UA(Tt−Ta)

Here ṁ uses the magnitude of loop flow. A negative heat-transfer rate means the tank is losing heat to the colder collector.

What is simplified?

  • Textbook constants: g = 9.80665 m/s² and cp = 4182 J/(kg·K).
  • Illustrative parameters: collector efficiency, heat-loss coefficients, pipe length, fitting losses and thermal capacities.
  • Illustrative model: one collector node and one fully mixed tank; no vertical stratification, pipe heat storage, pump, phase change, boiling, freezing or valve leakage.
  • Water properties: empirical density and viscosity correlations over the liquid-water range; the displayed temperatures are kept below 100 °C.
  • Not a design tool: real systems need correctly sized components, pressure protection and freeze protection.