Corrected work delivered to the shaft
Joule’s Paddle Wheel: Mechanical Equivalent of Heat
Can falling weights make a thermometer rise? Rebuild the experiment that put a number on the exchange between work and heat.
Water-friction calorimeter
Predicted rise before measurement noise
Take a trial to estimate the constant
Experiment against theory
Numerical checks
Checks use separate calculations, not the displayed trial result. All reference quantities are labelled by source or model.
772.692 ft·lbf per lb·°F
Joule’s corrected water-series result, reported in 1850. Reconstructed from his 40 friction trials and 40 radiation controls, the one-standard-error uncertainty is approximately ±2.06 ft·lbf per lb·°F (±0.011 J/cal). This is a retrospective estimate, not a confidence interval printed by Joule.
FIELD NOTESThe science
From falling weight to heat
The falling weights do work on the shaft. The rotating arms shear the water against stationary vanes; viscous dissipation turns mechanical energy into internal energy. In the ideal calorimeter model:
Here meff includes Joule’s measured pulley-and-string friction correction, N is the number of descents, and meq includes the water plus the water-equivalent heat capacity of the copper can, brass wheel and stopper. The estimated constant is:
The measurement noise
- Thermometer quantisation: each start and finish reading is rounded to the selected step. Joule reported that 0.005 °F was appreciable to his eye.
- Room heat leak: a paired no-motion radiation reading is subtracted. Joule measured a response of 0.04654 °F per degree of room-to-apparatus difference over a 35-minute experiment.
- Residual drift: a Gaussian residual is sampled for the paired correction. Its default scale is inferred from the scatter of the original 40 paired trials after removing thermometer quantisation.
- Fall reading: total descent is rounded to the 0.01-inch precision shown in Joule’s table.
What this reconstruction simplifies
The visual mechanism is schematic, not a dimensional replica. The shaft is represented by a stable fixed-step falling-mass model with a viscous terminal-speed approximation. The calorimeter is treated as well mixed; heat capacity is lumped into a water-equivalent mass; the paired blank correction is assumed to share the same mean room offset. The original experiment also included corrections for the changing mean temperature, string elasticity, pivot friction, buoyancy and heat exchange. The historical replay uses the published aggregate corrections rather than pretending every modern uncertainty is known.
Independent educational reconstruction. Not affiliated with James Prescott Joule, the Royal Society, or any museum or university.