THERMAL STORAGE · WATER SYSTEMS

Thermal Stratification in a Hot-Water Storage Tank

A cylinder can hold hot and cold water at once. Follow the invisible boundary that makes the stored heat useful — and watch flow and mixing erase it.

MODEL1D · 48 LAYERSILLUSTRATIVE WATER
LIVE CUTAWAYVertical storage cylinder
DRAWING HOT WATER
HOTCOLD
OUTLET TEMPERATURE60.0 °CTop outlet · draw mode
MEAN TANK TEMPERATURE37.0 °CVolume-averaged water temperature
USABLE HEAT ABOVE 40 °C4.6 kWhₜₕSensible heat above the 40 °C reference
THERMOCLINE THICKNESS18 cm10–90% temperature transition
THE EXPERIMENT

Change the conditions

TEXTBOOK CONSTANTS · ILLUSTRATIVE SETTINGS

Operating mode

i

Starting conditions

SELECT A REGIME
200 L
80 L300 L
1.50 m
1.0 m2.0 m
6.0 L/min
1 L/min18 L/min
12 °C
5 °C80 °C
0.15 cm²/s
0.00143 cm²/s5 cm²/s
1.2 W/m²K
0.2 W/m²K8 W/m²K
18 °C
5 °C25 °C
SCALED CLOCK 60× · FIXED 0.2 s STEP
MEASURE IT · EXPERIMENT 01

Does the front travel at the flow speed?

Turn off mixing and wall losses in a clean test, move one quarter of the tank volume through the inlet, then locate the 40 °C boundary. Compare the measured height with ideal plug-flow displacement.

Awaiting measurement · current tank geometry and flow will be used.
MODEL VERIFICATION

Three independent checks

01 · COOLINGCHECKING

Newton cooling law

Uniform tank, no flow or mixing. The numerical temperature is compared with the analytic exponential cooling solution.

NUMERICAL—
ANALYTIC—
Relative difference —
02 · DIFFUSIONCHECKING

Thermal eigenmode decay

A cosine temperature profile with insulated ends decays at a known rate. Its measured amplitude is compared with the diffusion equation.

NUMERICAL—
ANALYTIC—
Relative difference —
03 · ADVECTIONCHECKING

Plug-flow front position

A sharp inlet step is advected through the tank with zero physical mixing. The 40 °C crossing is compared with volume displacement.

MEASURED—
IDEAL—
Relative difference —

Checks use the selected geometry, flow, mixing and insulation settings. Small finite-volume differences are expected; the model is educational, not a certified tank-design tool.

MODEL NOTESThe science+

Governing model

The tank is divided into 48 equal-volume horizontal layers. Each layer has a water temperature T. Vertical transport is represented by a one-dimensional advection–diffusion energy equation:

∂T/∂t + u ∂T/∂z = α ∂²T/∂z² − kloss(T − Troom)

Here u is the signed mean vertical velocity, α is effective axial thermal diffusivity, and kloss = UAwall/(ρcpV). The flow speed is |u| = Q/A. Charging sends hot water in at the top; drawing sends cold water in at the bottom.

Constants and assumptions

  • Textbook: water density ρ = 997 kg/m³ and specific heat cp = 4180 J/(kg·K), treated as constant.
  • Textbook: gravity establishes the stable buoyancy ordering; warm water is less dense than cold water over the displayed range.
  • Illustrative: the effective axial diffusivity combines molecular conduction with unresolved jet and turbulence mixing.
  • Illustrative: the wall coefficient and inlet temperature are user-selected scenarios, not measured specifications.

What is simplified

This is a one-dimensional, cross-section-averaged model. It does not solve the full Navier–Stokes equations, resolve inlet diffuser geometry, predict a real coil plume, or calculate temperature-dependent water properties. Radial gradients and fittings are omitted. The stable hot-over-cold arrangement is physically motivated, while the rate of mixing is represented by one effective parameter.

Numerical method

Conservative finite-volume fluxes move heat between layers. Internal diffusion fluxes cancel pairwise, while the inlet and outlet carry enthalpy across the tank boundary. A fixed 0.2 s time step and second-order Runge–Kutta (Heun) update advance the layer temperatures. The chosen step remains below the advection and diffusion stability limits across the control ranges.

Educational physical model · no external data or network connection · not a design specification for a domestic hot-water system.