A-LEVEL SCIENCE × MATHEMATICAL PUZZLE № 028

Thermal Maze.

Build a wall. Bend the heat. Can you stop a thermal leak before it reaches the cold side?

01 Place materials02 Probe the field03 Solve the puzzle
YOUR
MISSION
I.Apply Fourier’s law to heat flow.
II.Identify and repair thermal bridges.
III.Interpret 2D temperature fields and energy balance.
THE ACTIVE EXPERIMENT

Conduction field / 01

Each square is 25 × 25 cm. One metre of wall depth. Left face: 80 °C. Right face: 10 °C.

SOLVED FIELD • CONSERVATIVE
HEAT SOURCEFOURIER CONDUCTION HEAT SINK
TH80°HOT FACE
TC10°COLD FACE
0 m0.250.500.751.001.251.50 m
YOUR MATERIAL KIT

Choose a thermal tile ↘

FOUR SCIENTIFIC SPECIMENS

Start from a specimen

Presets replace the full wall design. A new exercise may also load a specimen automatically.

THE LABORATORY NOTEBOOKKeep a record of every design.Snapshots log the calculated power, probe temperature and material layout.
00RECORDS
THE INTERACTIVE EXAM ROOM

The challenge deck / 02

Eight new science questions each session. Calculate, predict, repair, explore.

QUESTION 01 / 08BEGINNER
NUMERICAL REASONING

THE SCIENCE BEHIND THE MAZE

Field guide / 03

01 / THE LAW

Fourier's law

Heat travels down a temperature gradient. A high thermal conductivity k produces greater heat flow for a given geometry.

Q̇ = k A ΔT / L
For a uniform, one-dimensional slab.
02 / THE NETWORK

Two-dimensional balance

Each square exchanges energy with its neighbours. The solver balances every cell’s incoming and outgoing heat without creating energy.

Σ Gᵢⱼ(Tᵢ − Tⱼ) = 0
G = A / (d/2kᵢ + d/2kⱼ) at a shared face.
03 / IN THE WORLD

Thermal bridges

Metal studs and poorly insulated junctions offer low-resistance paths. Architects use continuous insulation to reduce winter heating demand.

R = L / (k A)
Thermal resistances add through layers in series.
MODEL BOUNDARIES & ASSUMPTIONS

A steady-state, isotropic conduction model with constant material conductivity. Each tile is 0.25 × 0.25 m, with 1 m depth. The left and right boundaries are fixed at 80 °C and 10 °C; top and bottom are insulated. No radiation, air movement, heat storage, moisture, contact resistance or temperature-dependent conductivity is included. Numerical temperatures are cell-centre averages, not direct laboratory measurements. These are intentionally illustrative wall conditions, not a building energy rating.

Made with 🤖 ChatGPT