THE SCIENCE OF KEEPING WARM

Thermal Atelier.

Build the layers. Follow the heat. Discover what makes a house warm.

EXPERIMENT / 001

01 — LIVE EXPERIMENT

The little house

PAUSED
Choose a material, then click a highlighted part of the house. Drag materials onto the house on desktop.
OUTSIDE AIR3°CTHERMAL SCAN / LIVE 19.0°C 0 W 0 W 0 W R W F
Warm indoor zoneHeat flow (W)Installed layers
INDOOR TEMPERATURE19.0°C
HEAT LEAVING HOUSE0W
OVERALL HEAT LEAK0W/K
HEATING ENERGY USED0.00kWh

Where is the warmth escaping?

LIVE SHARE OF HEAT FLOW
Roof
0%
Walls
0%
Floor
0%
Draughts
0%
00h 00m

03 — LAB NOTEBOOK

Follow the temperature

LIVE TRACE
Inside Outside Setpoint00:00 elapsed
STEADY 24-HOUR HEAT LOSS*0.0 kWh
HEATING RUN COST*£0.00
MATERIALS COST*£0

*Idealised estimates. Daily loss assumes today's indoor/outdoor temperature difference remains fixed for 24 h. Heating electricity is charged at an illustrative £0.26/kWh; materials are not current quotes.

04 — TEST YOUR THINKING

Heat-loss field test

BEGINNER
QUESTION 1 / 80 solved

EXPERIMENT

Loading challenge…

05 — UNDER THE SURFACE

What is the model actually doing?

Heat flows from hotter places to colder places. The thicker a useful insulator is, and the lower its thermal conductivity, the harder it is for heat to cross it. Our little house balances heater energy against heat escaping through three building sections and ventilation.

THERMAL RESISTANCER = d / λ

d in metres; λ in W/(m·K). Layer R-values add.

HEAT TRANSFER RATEQ̇ = AΔT / R

W through a section; A is surface area (m²).

INDOOR ENERGY BALANCEC dT/dt = P − GΔT

G = Σ(A/R) + ventilation, in W/K.

Scientific assumptions and limitations +

This is a single indoor-temperature thermal-mass model, not a full building-energy assessment. Roof, walls and floor are treated as parallel one-dimensional heat pathways with fixed areas; the floor is assumed to face the same outside temperature. Each pathway includes a simplified constant base resistance (including construction and surface effects), plus one chosen insulation layer. Ventilation and draughts are represented by a fixed 22 W/K, independent of weather. Effective heat capacity is a fixed 14 MJ/K. No solar gain, occupants, moisture transport, thermal bridges, changing conductivity, or air-source heat-pump efficiency is included. An electric-resistance heater is idealised as 100% heat efficient, with an on/off thermostat and a ±0.25°C deadband. The house artwork is illustrative, but all heat-rate values and temperature curves follow the stated equations.

By the end, you can:01 / Explain heat transfer and insulation02 / Calculate R-values, watts and kWh03 / Test which retrofits save heat

REAL-WORLD LINKS Home insulation · Building refurbishment · Fuel use · Winter heating · Energy bills