FIELD NOTES / ENERGY & INFRASTRUCTURE

The Hot-Water Boundary

A tank's hidden thermocline — watch the boundary between hot and cold water move, blur and survive.

INTERACTIVE MODELTEXTBOOK PHYSICS · ILLUSTRATIVE MIXING
SECTION VIEWSTRATIFIED
COLD RETURN THERMOCLINE HOT STORE DRAG TO PAN · COLOUR MAP: TEMPERATURE
THERMOCLINE THICKNESS 10–90% · ILLUSTRATIVE
0.00m
A narrow boundary stores heat cleanly
HOT LAYER ILLUSTRATIVE
0L
Above the 80% temperature level
OUTLET ILLUSTRATIVE
18.0°C
Bottom return · live model value
USEFUL HEAT ILLUSTRATIVE
0.00kWh
Water sensible heat · calculated
SUPERFICIAL FLOW · ILLUSTRATIVE0.00 mm/s
DIFFUSER JET · ILLUSTRATIVE0.000 m/s
EFFECTIVE DIFFUSIVITY · ILLUSTRATIVE0.00 × 10⁻⁶ m²/s
WHAT YOU'RE SEEING

A warm layer floats above cooler water. The thin transition zone is the thermocline: it separates useful hot storage from the cold return.

ILLUSTRATIVE NUMERICAL CHECKS

Numerical checks

3 / 3 PASS
01 · CONSERVATIONPASS
0.000%

Closed-tank heat balance drift

Target: 0% change in total heat
02 · ADVECTIONPASS
0.000%

Plug-flow centroid vs exact shift

Target: analytical travel distance
03 · DIFFUSIONPASS
0.000%

Gaussian width vs closed form

Target: σ² = σ₀² + 2Dt
BENCH EXPERIMENT↗

Measure diffusion

Isolate a warm Gaussian pulse, let the model spread it, then compare its measured width with the analytical prediction.

Awaiting measurement · uses the current effective diffusivity
MODEL NOTESThe scienceEQUATIONS, ASSUMPTIONS & LIMITS +

Governing equation

The tank is represented as a one-dimensional vertical water column. Height z is measured upward from the outlet; the inlet is at the top. Temperature follows an advection–diffusion equation with distributed wall exchange:

∂T/∂t + u ∂T/∂z = Deff ∂²T/∂z² − λ(T − Tamb)

The superficial velocity is u = −Q/A, where the negative sign represents downward charging flow. The wall-loss rate is λ = U As /(ρ cp V).

What sets the mixing?

Water's molecular thermal diffusivity is calculated from α = k/(ρcp). Inlet-jet mixing is represented by an illustrative axial-dispersion closure:

Deff = α + Cd vj dj
vj = |u|/r,   dj = Dtank√r

Here r is the diffuser open-area fraction and Cd = 0.008 is an illustrative, dimensionless dispersion coefficient. It is a teaching closure, not a universal diffuser correlation.

Numerical method and constants

The illustrative numerical grid uses 80 finite-volume cells. Face fluxes use first-order upwind advection and centred diffusion. An illustrative fixed 0.5 s Heun (explicit trapezoidal / RK2) step advances the temperature field. The time step is comfortably below the advection and diffusion stability limits over the available controls.

Textbook water properties: density 997 kg/m³, specific heat capacity 4182 J/(kg·K), thermal conductivity 0.60 W/(m·K). These are representative values near room temperature; real properties vary with temperature.

Simplifications and interpretation

The model assumes a constant cross-section, incompressible water, one-dimensional vertical transport, a fixed inlet temperature, and a well-mixed outlet face. It does not resolve the three-dimensional inlet plume, buoyancy-driven recirculation, tank fittings, temperature-dependent properties, or detailed wall layers. The initial smooth temperature boundary and the jet-dispersion coefficient are illustrative.

Consequently, use the model to explore mechanisms and compare regimes, not to size a real hot-water store. The displayed heat is sensible energy above the initial cold-water baseline; it is not a measure of system efficiency or deliverable heat at a specified load temperature.

Made with 🤖 ChatGPT