Illustrative one-zone heating model. The gas heat capacity is treated as constant, floor transfer is one-dimensional, and the upper room is fixed at 20 °C.
R = d/(kA) + 1/(hA)
NTU = 1/(Rṁcₚ)
Tₒ = Tᵣ + (Tᵢ − Tᵣ)e−NTU
Q = ṁcₚ(Tᵢ − Tₒ)
Tₛ = Tᵣ + Q/(hA)
Assumed parameters: A = 18 m², k = 1.1 W/(m·K), h = 8 W/(m²·K), cₚ = 1005 J/(kg·K). These are educational modelling choices, not measured properties of an individual Roman building. The actual exhaust, stratification and combustion process would be more complex.
Independent check: Qconducted = kA(Tgas,eff − Tₛ)/d. The effective gas temperature is obtained from the exact log-mean temperature difference of the assumed model.
The structures, flow particles and human-scale marker are illustrative reconstructions. Historical use of pilae and underfloor furnace gases is well established; specific architecture and proportions here are schematic.
Illustrative reconstruction, not an official model and not affiliated with any institution, company or manufacturer.