The science
What you see. A transparent demonstrator vortex tube on a bench: compressed air enters tangentially through six ports, spirals to the far end along the wall and leaves through a valve as a hot stream, while the part that is turned back along the axis leaves at the other end as cold air. Two thermometers show the end temperatures; the plug position follows the cold fraction you choose.
Flow and first law. The nozzles are choked, so the mass flow is m = Cd A p0 √(γ/(R T0)) (2/(γ+1))(γ+1)/(2(γ−1)). The tube has no heat input and does no work, so the enthalpy leaving equals the enthalpy entering: μ cp (Tc − T0) + (1−μ) cp (Th − T0) = 0. The cooling power therefore equals the heating power exactly.
Second law. Entropy generation Sgen = m [μ cp ln(Tc/T0) + (1−μ) cp ln(Th/T0) + R ln(p0/pa)] must not be negative. The big positive term is the throttled pressure ratio: a vortex tube wastes most of the compression energy, which is why its cooling per unit of compressor work is small. A reversible isentropic expansion of all the air, T0(1 − (pa/p0)R/cp), generates no entropy and is drawn as the reference line in the first graph; the real cold drop reaches only a fraction of it.
The empirical part. How much of that reference drop a tube reaches depends on its geometry, and there is no accepted closed-form theory. The cold drop here is q · ΔTisentropic · 0.55 (1−μ)1.1 (1 − e−μ/0.06), a fit with the shape of published commercial-tube curves (best cold temperature near μ = 0.2, best cooling power near μ = 0.6), not a measurement of one product. The swirl picture is a separate Rankine-vortex calculation: the centrifugal pressure gradient dp/dr = ρv²/r with an isentropic p–T relation shows how much cooler the static temperature at the axis can become from that effect alone; the real mechanism also involves the stagnation-temperature transport between the two vortices and is still debated.
Honest simplifications. Constant specific heats of dry air; the particles are a kinematic picture (a core stream going back and an outer stream going forward, coloured by a schematic temperature), not a CFD solution; the Rankine core radius is fixed at 0.7 of the bore; ambient exit pressure at both ends; no moisture or frost. The cooling per unit of compressor work (about 0.1) shows why vortex tubes are used for spot cooling where simplicity matters, not where efficiency does.
Checks. (1) The first-law balance closes over a grid of states; (2) entropy generation is positive everywhere in the standard range and exactly zero for an isentropic expansion; (3) the numerical maximum of the isentropic mass flux gives the choked closed form and the critical pressure ratio; (4) the Runge–Kutta integration of the vortex pressure gradient equals the exact exponential; (5) the swirl-chamber volume integrated from the Blender mesh equals the cylinder formula.