Pressure Budget: Finding the Heat-Pipe Limit
The capillary limit is a pressure balance, not a magic temperature. Scrub the load and watch the available head disappear.
STEADY-STATE MODEL
ENGINE v1.0 · SEED 641827
The science / assumptions
The capillary limit is the positive heat load at which ΔPcap − ΔPgravity = ΔPl + ΔPv. Water properties vary with temperature using compact correlations; saturated vapour is treated as an ideal gas. Vapour friction uses laminar Poiseuille-equivalent Darcy friction below Re 2,300 and a smooth-pipe Blasius fit above Re 4,000, with a linear transition between them. Contact angle is fixed at 20°; the outer radius is 6 mm; the wick flow area is the annulus between the wall and vapour core.
Illustrative, steady, one-dimensional model. It omits sonic choking, entrainment, boiling and viscous limits, local bend losses, non-condensable gases, and detailed two-phase wick microstructure. Property fits and geometry are educational approximations, not a product rating. The independent readout is a second root solution using the Illinois false-position method; the primary limit uses bounded bisection.
Illustrative design, not affiliated with any real institution or manufacturer.
Reading the instrument
Pressure ledger: the horizontal capillary head must cover liquid, vapour and adverse gravity terms. Values are model outputs. Compare the current load with the independently solved capillary limit; a pressure margin below 1.00 indicates the simplified return path cannot sustain the selected load.
The in-browser engine check runs eight deterministic numerical tests on this same page.