THERMOBED / ENGINEERING LAB
Packed-bed thermal storage
MAP · PACKED-BED THERMAL STORAGE

Packed-Bed Thermal-Hydraulic Design Map — Parameter Explorer

Find the operating region where heat transfer and pressure loss make sense together.

Textbook correlations · illustrative scenario · SI units
DESIGN MAPMODEL VIEW · LIVE
Ready · press Play to calculate the transient responseCanvas 2D · local model

How to read the map

Horizontal position is particle diameter; vertical position is superficial velocity. Select a cell to transfer that design into the shared scenario.

Design logic

Pressure loss rises strongly as particles shrink and flow accelerates. Heat-transfer coefficient and ideal front time move differently, so no single contour is universally best.

Independent numerical check

Ergun pressure drop is independently recalculated from the displayed geometry and fluid properties.

The science · equations and assumptions

Schumann two-temperature model. Fluid advection and solid storage are coupled by interphase convection:

ε ρf cpf ∂Tf/∂t + ρf cpf us ∂Tf/∂z = h as (Ts − Tf)
(1−ε) ρs cps ∂Ts/∂t = h as (Tf − Ts)
Nu = 2 + 1.1 Reₚ⁰·⁶ Pr¹ᐟ³
h = Nu kf / dp
ΔP/L = 150 μ (1−ε)² us /(ε³ dp²) + 1.75 ρf (1−ε) us² /(ε³ dp)
tfront ≈ (1−ε)ρs cps L /(ρf cpf us)

Definitions: ε void fraction; us superficial velocity; dp equivalent particle diameter; as = 6(1−ε)/dp; Reₚ = ρf us dp/μ. The front-time estimate assumes a sharp front and neglects fluid sensible capacity.

Simplifications: one-dimensional plug flow, constant representative properties, spherical-equivalent particles, no axial/radial conduction, no heat loss to surroundings, no radiation, and no dispersion. The fluid-solid exchange is integrated exactly within each finite-volume cell; axial advection uses first-order upwinding.

All displayed material properties and scenarios are illustrative; they are not calibrated to a particular installation. Pressure loss uses the Ergun packed-bed correlation.

Illustrative design, not affiliated with any real institution or manufacturer.

THERMOBED · packed-bed sensible-heat storageModel outputs are illustrative, not measured data.