MODULE 03 / PACKED-BED THERMAL STORAGE
Thermocline Instrument Bench
Measure the moving front with noisy thermocouple stations and repeat runs.
Instrumented packed bed
Three axial thermocouple stationsStation 25%
25.0 °Csensor 1 · x/L = 0.25Station 50%
25.0 °Csensor 2 · x/L = 0.50Station 75%
25.0 °Csensor 3 · x/L = 0.75Simulation time · 0.00 h
Repeatability record
No run recorded| Station | Mean | Std dev | n |
|---|---|---|---|
| Take a reading to populate the bench record. | |||
The science · model assumptions
Ceff ∂T/∂t + ρf cp,f us ∂T/∂x = keff ∂²T/∂x²
vT = ρf cp,f us / Ceff · αeff = keff / Ceff
Ceff = (1−ε)ρscp,s + ερfcp,f. The model assumes local thermal equilibrium between gas and solid, constant properties, one-dimensional axial flow, a fixed inlet temperature and an adiabatic wall. Axial conduction/dispersion is represented by keff. It neglects separate gas/solid temperatures, radial gradients, wall losses, pressure drop, moisture and temperature-dependent properties. The finite-difference solver uses upwind advection and central diffusion with a stability-limited time step. Values are illustrative, not a plant design basis.