STRATATHERMAL STORAGE LAB
Open this experiment in…
MODULE 05 / PACKED-BED THERMAL STORAGE

Thermal Storage Design-Space Explorer

Sweep flow and porosity to expose the storage-versus-breakthrough trade-off.

Illustrative model1D · LTE

Design-space map · nominal breakthrough time

Sweep pass · 1 / 192
Play scans the full operating grid; pause to inspect a cell.
Longer breakthrough timeShorter breakthrough timeDerived from vT = ρf cpf us / Ceff
Selected breakthrough
—nominal L/vT · h
Full-bed capacity
—kWh sensible
Selected front speed
—m/h
The science · model assumptions
Ceff ∂T/∂t + ρf cp,f us ∂T/∂x = keff ∂²T/∂x²
vT = ρf cp,f us / Ceff   ·   αeff = keff / Ceff
Ceff = (1−ε)ρscp,s + ερfcp,f. The model assumes local thermal equilibrium between gas and solid, constant properties, one-dimensional axial flow, a fixed inlet temperature and an adiabatic wall. Axial conduction/dispersion is represented by keff. It neglects separate gas/solid temperatures, radial gradients, wall losses, pressure drop, moisture and temperature-dependent properties. The finite-difference solver uses upwind advection and central diffusion with a stability-limited time step. Values are illustrative, not a plant design basis.
Made with 🤖 ChatGPT