Packed-Bed Charge Experiment — Instrumented Test Bench
Operate the test rig, read the thermocouples and quantify measurement noise.
Measurement chain
Five virtual thermocouples sample the fluid-temperature field. Gaussian-like deterministic noise is applied to the synthetic readings after the physical calculation.
Repeatability
Run repeated trials to see the spread caused by sensor noise. Export the current sensor record as CSV for further analysis.
Independent numerical check
Ergun pressure drop is independently recalculated from the displayed geometry and fluid properties.
The science · equations and assumptions
Schumann two-temperature model. Fluid advection and solid storage are coupled by interphase convection:
Definitions: ε void fraction; us superficial velocity; dp equivalent particle diameter; as = 6(1−ε)/dp; Reₚ = ρf us dp/μ. The front-time estimate assumes a sharp front and neglects fluid sensible capacity.
Simplifications: one-dimensional plug flow, constant representative properties, spherical-equivalent particles, no axial/radial conduction, no heat loss to surroundings, no radiation, and no dispersion. The fluid-solid exchange is integrated exactly within each finite-volume cell; axial advection uses first-order upwinding.
All displayed material properties and scenarios are illustrative; they are not calibrated to a particular installation. Pressure loss uses the Ergun packed-bed correlation.
Illustrative design, not affiliated with any real institution or manufacturer.