Packed-Bed Charge Cycle — Thermal Design Challenge
Meet the outlet-temperature target without exceeding the blower pressure budget.
Design brief
Reach an outlet temperature of at least 430 K within 3,600 s while keeping total bed pressure drop below 1.8 kPa.
Scoring
Passing both constraints earns a score based on remaining pressure margin and unused time. A failed run returns a targeted hint.
Independent numerical check
Ergun pressure drop is independently recalculated from the displayed geometry and fluid properties.
The science · equations and assumptions
Schumann two-temperature model. Fluid advection and solid storage are coupled by interphase convection:
Definitions: ε void fraction; us superficial velocity; dp equivalent particle diameter; as = 6(1−ε)/dp; Reₚ = ρf us dp/μ. The front-time estimate assumes a sharp front and neglects fluid sensible capacity.
Simplifications: one-dimensional plug flow, constant representative properties, spherical-equivalent particles, no axial/radial conduction, no heat loss to surroundings, no radiation, and no dispersion. The fluid-solid exchange is integrated exactly within each finite-volume cell; axial advection uses first-order upwinding.
All displayed material properties and scenarios are illustrative; they are not calibrated to a particular installation. Pressure loss uses the Ergun packed-bed correlation.
Illustrative design, not affiliated with any real institution or manufacturer.