Historical: two weights of 203066 and 203086 grains; 20 descents, 1260.248 in total per weight, 35 min; water equivalent 97470.2 grains. Joule reported 772.692 ft·lbf per lb·°F (vacuum corrected).
Textbook: W = 2mghN; C = meq × J; C dT/dt = P − K(T − Tair). Here J = 4.184 J/cal (thermochemical convention), meq in grams, and 1 cal is the conventional heat unit. Model uses effective heat capacity in cal/K.
Illustrative: calibrated net drive loss; uniform fall and rewind; single well-mixed temperature; Newton cooling. The original timing and reported thermometer readability anchor the model. Noise: independent Gaussian reading jitter with σ = half a division, quantisation by rounding, shared calibration offset (cancels), shared per-trial height error σ = 0.5 mm for the mean descent height and mass error σ = 0.5 g per weight. Those σ values are modelling assumptions, not published instrument uncertainties. Heat correction uses a simulated ambient reading and temperature history, not the hidden true temperature.
Estimate = corrected work / (water-equivalent grams × corrected rise). A weak or negative rise is rejected; bars for repeated trials show t-based random uncertainty only. Historical interval uses a subset of original rows with a common approximate correction. Real water heat capacity varies with temperature; the historical water unit is not exactly the thermochemical calorie.
Source: J. P. Joule, On the Mechanical Equivalent of Heat, Philosophical Transactions 140 (1850), 61–82, Table I and IX, doi:10.1098/rstl.1850.0004. Independent educational reconstruction, not affiliated with the Royal Society or Science Museum.