Weighing the
heat of motion.
Twenty descents. A brass paddle wheel. A rise in temperature almost too small to see. Repeat Joule’s experiment and weigh how much motion becomes heat.
The water tells the story
The gold trace is the observed, source-noisy rise. The dotted trace is the analytical prediction.
What did you measure?
Each completed trial becomes one estimate of the mechanical equivalent of heat.
Historical error bars: ±2.1 ft·lbf/(lb·°F) is a retrospective 1 SEM estimated from Joule’s forty paired temperature records, not a quoted 1850 uncertainty. Thomson judged the contemporary result within about 2–3 ft·lbf.
Three independent numerical checks
Internal tests check the equations—not whether a badly calibrated measurement deserves to agree with nature.
Sum every fall and compare with the total-drop expression.
Water heating plus transferred heat equals input work.
Empirical noise mean agrees with its independent source-based expectation.
05 / UNDER THE GLASSThe science behind the vessel
Conservation of energy
The falling pair does work on the shaft. After the pulley correction, the energy is shared between water, copper, brass, and exchange with the room.
Here meq is the water-equivalent heat capacity of vessel, paddles and stopper; the original was 4,240.5 grains. The illustrative modern reference is cp = 4,186.8 J/(kg·K), which depends slightly on temperature.
How the noise behaves
There is no invented bell curve. Each simulated trial draws an empirical corrected-temperature residual from the 40 paired friction and heat-exchange readings in Table I of Joule’s 1850 paper. These residuals are recentered so the expected simulated modern measurement is unbiased. A separate uniform ±0.0025 °F reading error represents half of his stated 0.005 °F discernible step. The strength control scales both.
The historical bar is a retrospective standard error propagated from the original forty corrected rises; it is not an error bar printed by Joule. A disabled correction can bias the result well outside this bar, without invalidating conservation of energy.
What is simplified
The vessel has a single well-mixed temperature. We integrate heat energy at a fixed 120 Hz simulation step and drive the graphic with the same energy fraction. Rope elasticity is scaled from Joule’s mean correction, friction is represented by an equivalent load, and room exchange is a tunable aggregate rather than a full thermal-flow model. The drawing is a historically inspired cutaway, not a dimensionally exact restoration. Twenty descents are visually compressed into seconds; Joule spent about 35 minutes per experiment.
Independent educational reconstruction for mysimulator.uk. Not affiliated with the Science Museum, historical archives, or the original researchers. Historical source: J. P. Joule, On the Mechanical Equivalent of Heat, Phil. Trans. 140 (1850), 61–82; K. Thomson’s contemporary uncertainty judgment, 1851. References also supplied in the article.