EXPERIMENT ARCHIVE / THE INTERACTIVE LAB
EXHIBIT 04 THERMODYNAMICS
REBUILT HISTORICAL EXPERIMENT / 1849—1850

Joule's Paddle Wheel / Weighing Heat

Can falling weights warm water by a measurable amount? Rebuild the apparatus, perform the experiment and calculate heat's mechanical equivalent.

DISPLAY
LABORATORY VIEW / SECTIONAL APPARATUS
READY TO MEASURE
↔ DRAG TO INSPECTRECONSTRUCTION · NOT TO SCALE
Wind the weights, then release them to turn brass paddles inside the copper vessel.
WORK DELIVERED ⓘ
0 J
0 / 20 descents
TRUE WATER RISE ⓘ
0.000 °C
theory · live
THERMOMETER RISE ⓘ
— °C
awaiting reading
YOUR MEASURED RESULT ⓘ
— J/cal
awaiting experiment
EVIDENCE DESK

One constant. Three ways to check.

0 RUNS RECORDED
EXPERIMENT vs THEORY
—Release the weights to take a reading.
STROKE SUM vs mgh0.0000% PASS
RK4 vs ANALYTIC COOLING0.0000% PASS
ENERGY CONSERVATION0.0000% PASS
FROM THE 1850 PAPER
772.692 ft·lbf per lb·°F

Joule's water-series result, corrected to vacuum.

RECONSTRUCTED ORIGINAL ERROR BAR
±2.18 ft·lbf · 1 standard error

Computed from 40 paired friction and blank runs; not a published error bar.

MODERN CALORIE CONVENTION
4.184 J/cal

Thermochemical calorie, defined exactly. A reference, not historical data.

DEEPER LOOKThe science behind the apparatus+

Energy carried by the weights

Two weights lose gravitational potential energy. Allowing for mechanical transmission: W = 2 m g h N η. With the water and vessel treated as one well-mixed calorimeter, C = (mw + meq)c.

Heat exchanged with the room

The model solves C dT/dt = W/trun − k C (T − Tair) using an exact, stable update each 1/60 s. Its closed-form solution independently verifies the numerical integration. Apparatus equivalent: 0.2748 kg of water. Historically derived room-loss slope: 0.04654 °F per °F difference over 35 minutes.

What an observer actually reads

The physical heat leak is Newtonian, not random. Each reading includes Gaussian observer noise followed by rounding to 0.005 °F, a shared calibration offset, and a small slow random drift. The latter noise parameters are explicit illustrative models; original calibration and readable resolution came from Joule's text. The blank-run correction removes predictable ambient exchange, not random noise.

Where this model stops

It simplifies a three-dimensional turbulent liquid to a uniform temperature; shaft acceleration, conduction gradients, changing specific heat, winding transients, frictional sound, and room fluctuations are omitted. A deliberate failure preset makes the signal smaller than measurement noise. Reconstruction for education, not affiliated with any museum or historical institution.

Made with 🤖 ChatGPT