Joule’s Paddle Wheel:
Weighing Heat
What does it take to warm water by a fraction of a degree? Let two lead weights fall, watch a brass paddle turn, and measure what the motion becomes.
EXPERIMENT
The weights are raised. Release them to turn the paddle and warm the water.
From a falling weight to a number.
Every release adds one experimental point. Unlike an ideal demonstration, a measured temperature can be noisy enough to obscure the effect.
∑ The science Equations, assumptions, error bars & original apparatus+
What is actually solved?
The descending masses do gravitational work. Mechanical loss at the pulley is subtracted; the remainder is dissipated by the paddles in water and metal.
The solver uses fixed time steps of 1/120 simulated second. The closed-form Newton-cooling solution is evaluated separately, rather than reused by the integrator.
How is a constant measured?
Each endpoint thermometer reading has independent Gaussian error with the selected standard deviation and is rounded to Joule's reported appreciable increment: 1/200 °F = 0.00278 °C. A matched no-stirring blank removes ambient drift; an analytical cooling correction recovers the injected heat.
This inversion is intentionally allowed to fail when the rise is negative or too small compared with its estimated uncertainty. Simulated runs use modern water physics; the historic estimate is a separate archival benchmark.
Original numbers and limits
Joule's water series used two lead weights of about 13.16 kg each, twenty descents of roughly 1.6 m, about 6.04 kg water, and an equivalent metal heat capacity of about 0.275 kg water. He obtained 772.692 ft·lbf per pound-degree Fahrenheit after a vacuum correction. Our reconstructed interval uses the scatter of forty friction readings paired with forty ambient-control readings in his Table I.
A water heat capacity of 4184 J/(kg·K) is a textbook approximation, not an exact universal constant. Vessel capacity is held fixed; the simulation simplifies spatial temperature gradients, rewinding, variable torque, evaporation, and instrument calibration drift. The picture is schematic, not to scale. This independent educational reconstruction is not affiliated with any museum or historical institution.
PRIMARY SOURCE — J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions of the Royal Society of London 140 (1850), 61–82, Tables I and IX. Apparatus cross-check: Science Museum Group collection, mechanical equivalent of heat apparatus.