Joule’s Paddle Wheel: Turning Work into Heat
Release both weights. Their lost gravitational energy will turn the brass paddles.
Work divided by heat
Ideal temperature rise (textbook model): —
Historical bar: reconstructed standard error from Table I, not an uncertainty published by Joule.
| Trial | Work J | Rise °C | Corrected °C | J/cal |
|---|---|---|---|---|
| No measurements yet. | ||||
All notebook observations are simulated; estimates use measured work and temperatures, not the true temperature.
The science Equations, sources & assumptions
Energy accounting
W = 2mghN × f; C = Meq × 4184; C dT/dt = P − K(T − Tair). For a constant-power segment, T(t+Δt) = Tair + (T−Tair)e−KΔt/C + (P/K)(1−e−KΔt/C).
Ĵ = Wmeas / (1000 Meq ΔTcorr). A calorie here is the historical water-based unit approximated by the modern thermochemical calorie. The true model uses 4184 J/kg/K (textbook convention), not a temperature-dependent water heat capacity.
Instrument model
Endpoint thermometer readings have independent Gaussian reading error (adjustable σ), common offset (σ = 0.01 °C), calibration gain (σ = 0.1%) and rounding to 0.005 °F (historical reading capability). Work has independent Gaussian relative error, σ = 0.05% (illustrative). The calibration gain is fixed per experiment campaign; offset cancels except for rounding. A separate blank cooling trial at 2 °C above ambient estimates K; the correction uses measured endpoint mean temperature. Noise distributions and calibration uncertainties are illustrative, not recovered historical instrument specifications.
Historical anchors
Joule's 1850 Table I: 40 water-friction trials, 20 descents per trial, 35 min per trial, 1260.248 inches mean cumulative fall; masses 203066 and 203086 grains. Water equivalent 97470.2 grains (water 93229.7, copper 2430.2, brass 1810.3). Corrected mean work 6067.114 ft·lbf, corrected rise 0.563209 °F; published vacuum equivalent 772.692 ft·lbf per lb·°F. Historical reconstructed uncertainty uses per-run rise corrected with 0.04654 times signed mean water–air difference plus 0.000102 °F, per-run corrected work and a fixed vacuum factor. Sample standard error, not a confidence interval or systematic uncertainty.
Drawing is a scaled interpretive cutaway, not a manufacturing plan. Rotation is visually slowed; rewinding is modeled as zero power into water. No fluid dynamics or temperature gradients are resolved. Model heat leak is Newtonian. Default net work factor matches the historical aggregate pulley, impact and string corrections. The historical cooling coefficient is approximated from the paper. Each modeled cycle includes a standardized preparation interval, including a final resting interval; the actual last cycle did not require rewinding. All slider alternatives are illustrative.
Source: J. P. Joule, On the Mechanical Equivalent of Heat, Philosophical Transactions 140 (1850), 61–82, DOI 10.1098/rstl.1850.0004, Plate VII and Tables I, IX. Unit definitions: NIST SP 811, Appendix B. Independent educational reconstruction; not affiliated with any museum or historical institution.