From falling mass to temperature rise
The corrected mechanical work is the loss of gravitational potential energy, plus the small elastic-string contribution Joule measured:
W = meff g h n + Wstring
The water, copper vessel and brass paddle share the heat. Their combined heat capacity is expressed as an equivalent mass of water:
Q = (mw + meq) cw ΔT
The inferred mechanical equivalent is:
J = W / (meq,total ΔT)
Historical apparatus. Joule used two lead weights, wooden pulleys and rollers, a brass wheel with eight sets of revolving arms, four sets of stationary vanes, a copper vessel and a calibrated mercury thermometer. The weights fell about 63 inches, were rewound, and descended twenty times per experiment.
Historical noise model. The simulator uses a Gaussian approximation to the published run-to-run scatter: 0.03595 °F for friction runs and 0.03524 °F for at-rest controls (sample standard deviations calculated from Joule’s forty readings in each group). Recorded temperature rises are rounded to the selected thermometer increment; the historical default is 0.005 °F. Room exchange uses Joule’s measured coefficient, 0.04654 °F of apparatus change per °F of room-to-vessel difference. His mean offsets were 0.305075 °F during friction runs and 0.322950 °F during controls; he applied the resulting 0.000832 °F differential correction and a further 0.000102 °F temperature-profile correction.
Original error bar. Combining the two independent standard errors gives about 0.00796 °F for the corrected mean rise. Propagating that through the inverse-temperature formula gives approximately ±10.93 ft·lbf per lb·°F at one standard error. This is a reconstruction from the published table, not an interval Joule printed.
Simplifications. The modern reference uses the specific heat of water and standard gravity. The fixed-step animation uses a regulated descent with exponential approach to Joule’s measured terminal speed; the heat model assumes the corrected mechanical work becomes heat in the vessel. One physical run is animated while the selected batch is sampled statistically. The model does not resolve local fluid turbulence or every thermal gradient.
Independent educational reconstruction; not affiliated with the Royal Society or the Science Museum Group.