The weight of one degree.
Recreate Joule’s falling-weight paddle wheel. Turn falling mass into stirring, stirring into heat—and a faint rise on a Victorian thermometer.
Can a falling weight warm water? Press Run experiment and watch the thermometer move by just a fraction of a degree.
One constant. Three centuries of scrutiny.
Joules of work per thermochemical calorie
The historical result is converted to a modern calorie convention for comparison. Scatter-only error bars exclude calibration and other systematic uncertainties.
Three independent checks
Temperature predicted analytically versus a one-second numerical solution.
WITHIN 0.2%Input work versus heat retained in the apparatus plus heat exchanged with air.
WITHIN 0.2%Analytical thermometer uncertainty versus 16,384 Monte Carlo repeats.
WITHIN 5%04 / UNDER THE GLASSThe science behind the instrumentEquations, noise model, historical method, and limitations+
Energy falls; temperature rises
Each descent supplies gravitational work W = 2 m g h N. A measured pulley-loss fraction removes work that never reached the copper vessel. In the water, a paddle converts mechanical energy into internal energy through viscous dissipation.
With water mass m₍w₎ and Joule’s copper-and-brass water equivalent m₍eq₎ ≈ 0.275 kg, C = (m₍w₎ + m₍eq₎) × 4184 J/(kg·K). The numerical model integrates C dT/dt = P₍paddle₎ − k(T − T₍air₎) in one-second steps. The ideal fixed-power, constant-air solution is ΔT(t) = P/k × (1 − exp(−kt/C)) when initially at air temperature.
A thermometer, not a random-number machine
Each thermometer observation is a true temperature plus Gaussian reading scatter (adjustable σ), then rounded to a 0.005 °F division. A common calibration offset cancels between readings; slow zero drift adds an independent 0.004 °F end-to-start difference. Cellar air fluctuates smoothly rather than as independent per-frame noise. An illustrative 3% calibration uncertainty applies to the separate heat-exchange correction. Repeat trials to see distributions emerge.
The original uncertainty
Joule’s 1850 paper lists 40 water-series runs but does not print a modern confidence interval. We reproduce each original fall distance and friction temperature rise and use his tabulated air offset and 0.04654 °F-per-°F control correction. The plotted 95% interval is reconstructed using Student’s t₍39₎ ≈ 2.023 and the scatter of the 40 individually inferred equivalents. We anchor it on Joule’s published 772.692 ft·lbf/(lb·°F), including his vacuum correction. It is not a claim about his total historical measurement uncertainty.
Original 1850 quantities are identified as historical. Thermal conductivity, stochastic noise, visual motion and precision settings are educational approximations, not exact replays of individual laboratory days. No measured data is fabricated or attributed to Joule.
The modern 4.184 J/cal is the exact thermochemical-calorie definition; water’s actual specific heat varies slightly with temperature. Historical and modern calorie conventions are not identical.
Reconstruction is independent and not affiliated with any museum, university, or historical institution.