Joule’s Paddle Wheel
Can falling weights warm water by a measurable amount? Rebuild the calorimeter, repeat the measurements, and recover the mechanical equivalent of heat.
The falling weights turn the brass paddles; friction raises the water temperature by a fraction of a degree.
Set the experiment
Historical values are labelled Joule 1850. Adjustable values and new noisy readings are illustrative repeats, not measurements made by Joule.
Read the thermometer
Each point is one independent trial. The amber series is your repeat; the grey record is transcribed from Joule’s original Table I.
Grey band: original mean ±1 SD. Amber whiskers: simulated thermometer quantisation. Joule did not publish modern confidence intervals.
| TRIAL | RISE (°F) | INFERRED J | STATUS |
|---|---|---|---|
| No readings yet. Run the experiment. | |||
What Joule actually measured
Joule reported the thermometer scale and individual observations, but no modern confidence interval. The SD and SEM above are recalculated from the 40 original friction rows.
Three independent checks
Modern conversion: 1 BtuIT = 1,055.056 J and 1 ft·lbf = 1.355818 J. The water heat-capacity model uses 4,186.8 J·kg⁻¹·K⁻¹.
05 / EXPLANATIONThe scienceEquations, noise model, assumptions and historical limits+
From falling mass to shaft work
Two weights drive the central roller. For one fall, the corrected work delivered to the paddle shaft is modelled as:
The kinetic-energy term removes the weights’ residual motion at the floor. Joule also corrected the measured drive for pulley and string friction, and added a small string-elasticity term. The simulation retains his correction as a scaled factor.
From work to temperature
The equivalent water mass includes the water plus the measured heat capacity of the copper vessel and brass wheel. The inferred constant is:
The measurement noise
- Empirical repeat scatter: εG is Gaussian with σ = 0.03595 °F, estimated from the sample standard deviation of Joule’s 40 original friction readings.
- Thermometer quantisation: εq is the difference of two independent uniform half-tick reading errors. The default tick is 0.00386 °F, reconstructed from 12.951 divisions per °F and one-twentieth-division reading.
- Room exchange: k = 0.04654 °F per °F room-to-apparatus offset over a trial, from Joule’s blank/radiation experiments. The blank-run switch removes this mean drift.
Simplifications
The falling weights are represented by a damped, fixed-step vertical motion model tuned to Joule’s reported terminal speed of 2.42 inches per second. The 40-run scatter is treated as Gaussian; this is an empirical approximation, not a claim that Joule’s errors were normally distributed. Water heat capacity is held constant, and the apparatus heat capacity is carried as a water-equivalent mass.
This is an educational reconstruction, not an instrument built or endorsed by the Science Museum Group or any historical institution.