Difference from modern specific heat of water (illustrative reference at 20 °C).
Joule’s Paddle Wheel
Can falling weights warm water by exactly the amount of work they deliver?
The calorimeter
What did you measure?
Historical result is about 0.64% below the modern reference after unit conversion.
Forward-predicted temperature rise versus the measured mean.
Percent difference between observed trial spread and analytical one-sigma noise prediction.
Joule’s five published series means
Values in ft·lbf per lb of water per °F-equivalent as tabulated by Joule. The spread is shown as historical context, not as formal error bars: the five series used different materials and methods.
OPEN NOTEBOOKThe science: equations, noise and assumptions+
Work becomes heat
Two equal masses descend through height h. Their gravitational work is W = 2mgh. In the idealised calorimeter, that energy warms water and the vessel: W = (mwc + Cv)ΔT. The estimated specific heat is therefore c = (W − CvΔT)/(mwΔT).
What makes a noisy repeat?
Each initial and final thermometer reading receives independent Gaussian noise, ε ~ N(0, σT²). The difference therefore has standard deviation √2 σT. A second Gaussian term represents the residual uncertainty in the heat-loss correction. The displayed uncertainty is propagated from these terms and reduced by √N for N independent runs. A small random repeat-to-repeat heat-leak residual is included; it is not a claim about Joule’s actual room conditions.
What is simplified?
The model assumes constant water heat capacity, a calibrated vessel heat capacity of 180 J K⁻¹ (illustrative), complete transfer of the corrected work into the calorimeter, and two equal descending weights. Real Joule corrected detailed observations for heat exchange, vibration, sound and apparatus effects. The 1850 paper does not give modern confidence intervals. Joule said his preferred value was probably slightly high because vibration and sound could not be eliminated.
Historical and modern numbers
Joule’s preferred water result was 772.692 ft·lbf to raise one pound of water by 1 °F. Using exact modern unit conversions, this is about 4,157.3 J kg⁻¹ K⁻¹. The comparison value used here is 4,184 J kg⁻¹ K⁻¹, a representative modern specific heat near room temperature. They are not identical definitions or measurement conditions.
Independent educational reconstruction; not affiliated with the Science Museum Group, the Royal Society or any historical institution.