Joule’s Paddle Wheel & the Price of Heat
Release two falling weights. Watch the brass paddles stir water. Then use a barely perceptible rise in temperature to weigh the cost of heat.
Falling-weight calorimeter
Temperature against time
Joule’s forty water trials
The error band is computed from the 40 published raw rises (sample SD), not a formal error bar Joule claimed for his final constant. Historic thermal-loss corrections were applied separately.
How close did you come?
Three independent cross-checks
Integrated paddle work versus change in thermal energy plus independently integrated room transfer.
Exact on/off-heating solution versus the fixed-step time integration.
Monte Carlo thermometer spread versus the independent Gaussian-plus-uniform prediction.
07 / UNDER THE HOODThe science, assumptions & sources
From falling weight to temperature
Net mechanical work is W = 2mghN × η, with gravitational acceleration g = 9.80665 m/s². The historical pulley-loss allowance is η = 403315 / 406152 ≈ 0.9930 for the reference setup; it is held constant as an illustrative simplification when sliders change.
Heat capacity is C = (m_water + 0.2748 kg) × 4185.8 J/(kg·K). The additional mass represents the copper/brass vessel's water-equivalent heat capacity, derived from Joule's published 4,240.5 grains.
Cooling and reading noise
The temperature difference from the starting water obeys dθ/dt = P(t)/C − k[θ − ΔT_room]. During a fall, power is constant; during rewinding, it is zero. Each fixed step is integrated by the exact exponential solution. A separate no-stirring control estimates ambient drift.
Each manual thermometer reading adds independent Gaussian scatter with user-selected standard deviation plus a uniform ±0.0025°F interpolation uncertainty, based on Joule's stated 1/200°F readability. This stochastic model is illustrative—not a fit to his instrument's residuals. The Monte Carlo check uses 4,096 independently drawn differences.
What is real, what is reconstructed?
The two weights, about 29 lb apiece, each descend about 63 in, repeated 20 times. Original records give 40 raw water-friction rises, average 0.57525°F, and a corrected heat rise of 0.563209°F. Joule's reported water equivalent in vacuo was 772.692 ft·lbf per pound-degree Fahrenheit. The modern comparison is about 777.98 in the same units, calculated from a water heat capacity near 15°C.
Visible machinery is an illustrative reconstruction, not a CAD scan. Speed, heat exchange, numerical ambient offset, and scatter can be adjusted; Joule also accounted for pulley friction, air buoyancy, vessel heat, and sound. A weak or negative measured rise yields an inconclusive result, not a fictitious constant.
Source notes & independence
J. P. Joule, “On the Mechanical Equivalent of Heat”, Philosophical Transactions 140 (1850), pp. 61–82, especially Tables I and IX; Science Museum Group, “Mechanical equivalent of heat apparatus”; NIST Guide to the SI, calorie at 15°C. The historical 40-trial SD shown above is recalculated directly from Table I.
Independent educational reconstruction. Not affiliated with any museum, publisher, or historical institution.