THE EXPERIMENT ARCHIVE/THERMODYNAMICS
Rebuilt historical apparatusManchester · 1850
FIELD NOTE 01 HEAT IS MOTION

Joule's Paddle Wheel: Rebuilding Heat from Work

Drop two lead weights. Stir a sealed copper vessel. Measure a temperature rise scarcely larger than a whisper.

ORIGINAL PAPER · WATER SERIES772.692ft·lbf per lb·°F · Joule, 1850
CALORIMETER RISE simulated reading
— °F
Awaiting a reading
PADDLE WORK modelled
0 J
20 descents at original settings
YOUR EQUIVALENT simulated measurement
— ft·lbf / (lb·°F)
The experiment's answer
FROM MODERN REFERENCE textbook comparison
— %
Reference ≈ 778.0 ft·lbf / (lb·°F)
01 / THE INSTRUMENT

Falling weight → turning paddles → warmer water

HIGH DETAIL
CUTAWAY RECONSTRUCTION NOT TO SCALE
READY TO MEASURE
00:00 / 35:00
○At rest. The two lead weights hold gravitational energy above the floor.DRAG TO SLIDE
03 / THE EVIDENCE

Forty historical readings. Your new ones.

0 NEW
40 original paired readings Your trials Modern ≈ 778.0
Historical reconstructed spread: ±13.8 ft·lbf (1 SD across 40 paired runs); not a published nineteenth-century confidence interval.
04 / INDEPENDENT CHECKS

Three ways to audit the physics

3 / 3 PASS
01   Gravity work——
02   Adiabatic calorimetry——
03   Cooling dynamics——
Independent force integral · energy integration · Runge–Kutta cross-check. Deviations expressed as percentages.
05 / THE SCIENCEWhat is actually being calculated?Show equations + assumptions

The central equation

The falling weights transfer mechanical work to eight sets of brass paddles turning between stationary vanes in a copper water vessel. Calorimetry relates the measured rise to the work delivered.

W = 2mghN × η   ;   W = CΔT + Qleak
Jequiv = Wft·lbf / (Mwater-eq,lb · ΔT°F,corr)

The heat capacity C = (mwater + mmetal,water-equivalent)c. The vessel and brass add approximately 0.275 kg of water-equivalent capacity. No nineteenth-century experiment reported an SI constant in the modern sense: the historical number denotes foot-pounds required to warm a pound of water through one Fahrenheit degree.

Noise, error bars and simplifications

The simulation samples with replacement from the 40 original paired readings after subtracting their resting-control changes. Their reconstructed net mean is 0.562275 °F and sample standard deviation is 0.010061 °F. These provide an empirical residual bootstrap, scaled by the noise control. Readout granularity is 0.005 °F; room fluctuations use a small illustrative Ornstein–Uhlenbeck model, not an unverified historical measurement.

Heating and Newton cooling are integrated at fixed one-second physical steps; the browser clock runs faster than the experiment. The correction switch uses a simulated heat-budget correction alongside the resting-control comparison. Joule's actual calibration and correction procedures were more detailed. The original 772.692 is compared with a rounded modern reference near 778.0 ft·lbf per lb·°F, which depends on the water-temperature convention. This exhibit is independently created and is not affiliated with any historical museum or institution.

Made with 🤖 ChatGPT