Energy balance
Two falling weights do work on the shaft. With weight per hanger P, drop height h, n descents and measured pulley loss fraction f:
W = 2P h n (1 − f) + Wstring
The calorimeter’s water-equivalent heat capacity is the water mass plus the measured thermal capacity of the copper vessel, brass paddle and stopper:
C = mwater + 0.605786 lb
The mechanical equivalent is estimated from the corrected temperature rise:
J = W / (C ΔTcorrected)
Real measurement noise
Each simulated thermometer difference contains independent endpoint quantisation at the selected increment. Run-to-run scatter is Gaussian, calibrated to the spread of Joule’s forty published friction readings. A separate matched radiation-control series models heat exchange with the room. Joule measured an exchange coefficient of 0.04654 °F per °F difference over a 35-minute trial.
The plotted original error bars are a reconstructed 1σ readability contribution: two independently rounded endpoint readings at 1/200 °F give an uncertainty of 0.005/√6 = 0.00204 °F in one temperature difference. Joule did not publish formal statistical confidence intervals; these are not presented as his own quoted confidence limits.
What is simplified?
The animated fall is accelerated for exhibit use. The weights are treated as moving at a damped terminal speed; the display’s paddle rotation is schematic. The numerical measurement uses the historical work and heat-capacity balance, not the animation’s visual speed. The copper vessel, water, brass wheel and stopper are represented by their combined water-equivalent heat capacity. The model assumes the measured pulley correction is applied correctly and that the matched control captures the room’s heat exchange.
An educational reconstruction based on Joule’s published paper. Not affiliated with the Royal Society, the Science Museum Group or any historical institution.