THE MEASUREMENT ROOMHISTORICAL EXPERIMENTS · ENERGY
REBUILT HISTORICAL EXPERIMENT

Joule’s Paddle Wheel

Can falling weights reveal the mechanical equivalent of heat?

ARCHIVE RECONSTRUCTION
APPARATUS / WATER SERIESGravity drives the paddles
READY · 0 / 20 DESCENTS
NOT TO SCALE · MOTION COMPRESSED ×50
↔ DRAG TO INSPECT

The descending weights turn the brass paddle wheel. Its friction warms the water by only a fraction of a degree.

MECHANICAL WORK / RUN6,067 ft·lbfcalculated from falling load
IDEAL TEMPERATURE RISE0.559 °Fmodern reference model
ROOM HEAT EXCHANGE+0.014 °Fper 35-minute run
YOUR MEASUREMENT

Mechanical equivalent

AWAITING READINGS
—ft·lbf / Btu
Take a batch to calculate the mean and 1σ uncertainty.
Difference from modern value—
Mean corrected temperature rise— °F
Historical correction applied0.998775 ×
The result will appear here after you take a batch of measurements.
EXPERIMENT VS THEORY

Where does the result land?

ft·lbf / Btu
Joule, 1850 · reconstructed 1σModern referenceYour result

Joule published no formal statistical error bars. The historical whisker is reconstructed from the scatter of his 40 water-friction trials; it is not a quoted uncertainty.

NUMERICAL CROSS-CHECKS

Three ways to audit the result

Each check reports its percentage difference.
01BRUTE-FORCE SUM

Fall-by-fall work ledger

0.000%

Numerical sum of each small weight displacement versus the closed-form work.

PASS · NUMERICAL AGREEMENT
02HISTORICAL REPLAY

Joule’s corrected rise

0.000%

40 paired friction and radiation entries reconstruct 0.563209 °F after Joule’s two small corrections.

PASS · TABLE I RECONSTRUCTED
03MONTE CARLO

Noise-model mean

—

10,000 resampled trials test whether the empirical noise stays centred on the analytical prediction.

READY · RUN A BATCH
04MODERN UNIT BRIDGE

Foot-pound to Btu

0.000%

778.17 ft·lbf/Btu agrees with 1,055.056 J/Btu divided by 1.355818 J/ft·lbf.

PASS · REFERENCE CONVERSION
FIELD NOTESThe science+

Energy balance

J = W / (Ceq × ΔTcorrected)

W = (mpair − mpulley) × htotal + Estring

Work is measured in foot-pounds force. The calorimeter capacity is expressed as the equivalent mass of water, in pounds, so heat is in Btu.

Heat capacity

Ceq = mwater + 0.34717 lb + 0.25861 lb

The fixed additions are Joule’s copper vessel, brass wheel, and stopper expressed as equivalent water masses. The thermometer was pre-warmed before immersion and was not included in the capacity total.

Thermal exchange and noise

ΔTread = ΔTideal + 0.04654 × ΔTroom + ε

ε is resampled from the 40 paired Table I friction/radiation residuals, centred on zero, with optional extra Gaussian readout jitter. The room term is removed only when the correction switch is on.

What is simplified?

The water is treated as uniformly mixed; heat capacities are constant; all counted mechanical work becomes heat in the calorimeter; and the room exchange is linear over one 35-minute run. The historical air-to-vacuum factor is applied after calculating the measured equivalent.

Historical caution

The 1σ historical bar is a modern reconstruction from published repeat readings, not an uncertainty Joule himself printed. It does not include every systematic uncertainty in the weights, heat capacity, or correction procedure.

This independent educational reconstruction is not affiliated with the Royal Society, the Science Museum Group, or any university.