Fall-by-fall work ledger
0.000%Numerical sum of each small weight displacement versus the closed-form work.
PASS · NUMERICAL AGREEMENTCan falling weights reveal the mechanical equivalent of heat?
The descending weights turn the brass paddle wheel. Its friction warms the water by only a fraction of a degree.
Joule published no formal statistical error bars. The historical whisker is reconstructed from the scatter of his 40 water-friction trials; it is not a quoted uncertainty.
Numerical sum of each small weight displacement versus the closed-form work.
PASS · NUMERICAL AGREEMENT40 paired friction and radiation entries reconstruct 0.563209 °F after Joule’s two small corrections.
PASS · TABLE I RECONSTRUCTED10,000 resampled trials test whether the empirical noise stays centred on the analytical prediction.
READY · RUN A BATCH778.17 ft·lbf/Btu agrees with 1,055.056 J/Btu divided by 1.355818 J/ft·lbf.
PASS · REFERENCE CONVERSIONJ = W / (Ceq × ΔTcorrected)
W = (mpair − mpulley) × htotal + Estring
Work is measured in foot-pounds force. The calorimeter capacity is expressed as the equivalent mass of water, in pounds, so heat is in Btu.
Ceq = mwater + 0.34717 lb + 0.25861 lb
The fixed additions are Joule’s copper vessel, brass wheel, and stopper expressed as equivalent water masses. The thermometer was pre-warmed before immersion and was not included in the capacity total.
ΔTread = ΔTideal + 0.04654 × ΔTroom + ε
ε is resampled from the 40 paired Table I friction/radiation residuals, centred on zero, with optional extra Gaussian readout jitter. The room term is removed only when the correction switch is on.
The water is treated as uniformly mixed; heat capacities are constant; all counted mechanical work becomes heat in the calorimeter; and the room exchange is linear over one 35-minute run. The historical air-to-vacuum factor is applied after calculating the measured equivalent.
The 1σ historical bar is a modern reconstruction from published repeat readings, not an uncertainty Joule himself printed. It does not include every systematic uncertainty in the weights, heat capacity, or correction procedure.
This independent educational reconstruction is not affiliated with the Royal Society, the Science Museum Group, or any university.