Joule’s Paddle Wheel: Measuring Heat from Work
Drop the weights. Stir the water. Measure the energy in a calorie.
A pair of suspended lead weights stores gravitational energy. Release them to start your trial.
How much work makes a calorie?
Run a trial to obtain a noisy measurement.
| Trial | Work (J) | Measured ΔT (°F) | Corrected ΔT (°F) | Ideal ΔT (°F) | Estimate (J/cal) | vs modern |
|---|---|---|---|---|---|---|
| No trials yet. Run the apparatus to record a measurement. | ||||||
Ledger includes only the current setup; changing a setting clears the ledger to avoid pooling unlike measurements.
Four independent checks
Checks test the model, not the accuracy of a noisy experimental estimate. A failed experiment can still have a valid numerical model.
The science Equations, assumptions & sources
Mechanical work and heat
W = η (m₁ + m₂) g H N. C = Mₑ c, with Mₑ = 6.316 kg (historical water-equivalent mass), c = 4,184 J/(kg·K) (textbook convention), g = 9.80665 m/s² (textbook standard), and η derived from the original pulley, impact and cord corrections.
C dT/dt = P(t) − K(T − Tₐ). During a fall P = ηmgv; during rewind P = 0. A fixed one-second physical step uses exact fall overlap and explicit Euler heat exchange; the separate closed-form calculation solves each constant-power segment analytically. A cycle lasts 105 s (historical mean); rewind is compressed visually. The water is treated as well mixed, and the cutaway is illustrative, not a dimensioned engineering drawing.
Measurement and uncertainty
Ĵ = W / [Mₑ(g) × (5/9) × ΔTcorrected(°F)]. Here Mₑ(g) means equivalent mass in grams, not gravity. The corrected rise subtracts a trapezoidal estimate of heat received from the room using the measured endpoints. Historical reading granularity is 0.005 °F (Joule’s stated approximate readability). The independent Gaussian endpoint error is inferred from Table I corrected friction residuals after accounting for rounding; the Gaussian law is illustrative, not a recorded historical distribution. Quantization is applied to each reading. The residual also includes unmodelled heat transfer and other disturbances, so its attribution to endpoint noise is an approximation.
Historical bars show a reconstructed standard error and 95% Student t interval from forty runs using each run’s fall, observed rise and mean air offset; the original article did not publish confidence bars. The archival ratio uses Joule’s aggregate work corrections and air-to-vacuum ratio. The modern thermochemical calorie is exactly 4.184 J by definition; water’s actual heat capacity varies with temperature. Simulated repeated-trial bars use sample standard error and are not full systematic uncertainty.
Sources
J. P. Joule, “On the Mechanical Equivalent of Heat”, Philosophical Transactions of the Royal Society of London 140 (1850), 61–82, Table I and IX, Plate VII. DOI: 10.1098/rstl.1850.0004. Science Museum Group, Mechanical equivalent of heat apparatus, collection object co2526. NIST SP 811, Appendix B (thermochemical calorie and unit conversions). Independent educational reconstruction; not affiliated with the museum or Royal Society.