Change the conditions
The measurement ledger
No observations yet. Run the apparatus to create real, noisy trial readings.
Three independent numerical checks
These compare independent calculations, not three copies of the same formula.
THE ORIGINAL EXPERIMENT, EXPLAINEDThe science behind the cellar
Motion becomes thermal energy
Two suspended weights supplied gravitational work. A brass wheel with eight sets of revolving arms moved between four sets of fixed vanes inside a copper vessel. Joule rewound the weights 20 times per water trial. The historical mean corrected work was 6,067.114 foot-pounds; the total apparatus heat capacity equalled 97,470.2 grains of water.
The measured temperature is altered by exchange with the room. We evolve water and vessel temperature together with Newton’s cooling law, holding power constant over the experiment:
For known leakage, a matching idle control and an exponential attenuation correction recover the work-caused temperature change. The inferred mechanical equivalent is work divided by the water-equivalent mass and the corrected rise, expressed in joules per thermochemical calorie.
Where the uncertainty comes from
Joule’s Table I contains 40 water-friction readings with an uncorrected mean rise of 0.57525 °F. Their sample standard deviation is approximately 0.03595 °F. The exhibit resamples deviations from these primary observations, then adds a separate illustrative Gaussian thermometer error. Joule himself said that roughly 0.005 °F was an appreciable reading.
The historical uncertainty bar shown here is our reconstruction: 1.96 × (original raw-reading standard deviation / √40), propagated approximately through the reported 0.563209 °F corrected mean. It is not a confidence interval that Joule supplied. The spread includes real environmental changes and is not a purified thermometer-noise estimate.
Honest simplifications
The vessel and water use a single lumped heat capacity; liquid turbulence, individual drop acceleration, pulley inertia, air currents and spatial temperature gradients are not resolved. The moving mechanism is an illustrative cutaway, not a dimensionally accurate engineering drawing. The experiment runs with accelerated time; the integrator still advances in fixed steps. High/Low only changes visual detail.
The modern comparison is the defined 4.184 J per thermochemical calorie. The historical 772.692 ft·lbf per pound of water per degree Fahrenheit converts to about 4.157 J/cal using exact unit conversions. Water’s actual heat capacity varies with temperature, so these are not identical conventions. No institutional affiliation is claimed.
J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions of the Royal Society of London 140 (1850), 61–82, especially Table I and Table IX, DOI: 10.1098/rstl.1850.0004. See also the scientific commentary “Heat, work and subtle fluids,” Phil. Trans. R. Soc. A (2015), DOI: 10.1098/rsta.2014.0348.