Can falling weights warm a vessel?
Work in. Heat out.
He published no formal confidence interval. The bars below are calculated from the 40 friction rises in his Table I, not claimed as his own error bars.
| Run | Corrected ΔT | Equivalent |
|---|---|---|
| Run the apparatus to collect readings. | ||
Does the reconstruction balance?
Independent calculations update with the controls. Differences are relative to the stated reference.
Direct work ÷ heat versus the displayed measurement formula.
Summed release-by-release work versus the aggregate fall calculation.
10,000 noisy repeats versus the analytic mean; difference is expressed as a percentage of one-run noise.
No-noise default reconstruction versus Joule’s corrected water result.
THE SCIENCEEquations, noise model and historical limits+
From falling weights to heat
The total corrected work is the corrected weight force times the total corrected fall, plus the measured string-elasticity term:
The calorimeter heat is the water-equivalent capacity multiplied by the corrected temperature rise:
The mechanical equivalent is work per thermal unit. The exhibit calculates it in foot-pounds per BTU, then applies Joule’s air-to-vacuum correction to compare with his final published number.
Why the temperature reading is noisy
Joule alternated friction runs with no-friction radiation/conduction controls. Both runs experience room-driven heat exchange. A matched idle control removes that common-mode drift; the mismatch slider deliberately leaves some behind.
Each simulated corrected rise combines Gaussian per-reading thermometer noise with Gaussian run-to-run process scatter. The latter is calibrated so the combined one-run spread reproduces the sample standard deviation of the forty published friction rises in Table I. For numerical stability, readings below 0.005 °F are displayed at that floor and should be treated as unresolved.
The animated drop uses a linear-drag model, integrated at fixed display steps with an exact exponential update: v′ = vt + (v − vt)e−Δt/τ. The visual clock is SCALED for the exhibit.
The thermometer scale uses 0.01 °F as a read-noise scale because Joule said his instruments agreed to about that amount. That comparison is not a formal statistical standard deviation.
Simplifications and provenance
- Textbook values: 406,152 grains of falling mass, 20 descents, 1,260.248 inches total fall, 97,470.2 grains water-equivalent heat capacity.
- Textbook corrections: 2,837 grains pulley friction, 0.0076 inch terminal-speed height correction per fall, and 0.8464 ft·lbf string elasticity per descent.
- The original paper gives no formal confidence interval. The displayed 1σ bars are reconstructed from the published Table I friction readings.
- The scene is a scaled 2D cutaway, not a dimensionally exact engineering drawing. The historical apparatus used two falling weights, pulleys, a central roller, a paddle wheel, fixed vanes and a copper vessel.
This educational reconstruction is independent and is not affiliated with the Science Museum Group, the Royal Society or any historical institution.