Gravity becomes internal energy: W = 2mghN(1−f). For a short, ideally insulated run, W = (mwater + mmetal,eq)cΔT.
Cooling: C·dT/dt = P − UA(T − Troom), with C = (mwater + 0.2748 kg)c and P constant during the accelerated reconstruction. The analytic solution is compared against an independent fourth-order time integrator.
Calibration: measured start/end temperatures include Gaussian readout noise, independent uniform resolution error and Gaussian drift. A separate ideal cooling calibration supplies the decay rate; ticking the box corrects ambient transfer and attenuation. It does not magically remove thermometer noise.
Limits: Historic weights, water mass, windings, heights, and benchmark are documented; noise distributions, visualisation speed, heat-leak coefficient, metal heat capacity held fixed and correction calibration are teaching approximations. A historical thermometer's reported appreciable increment was 1/200 °F, not a published Gaussian standard deviation. One fixed specific-heat reference is used rather than its temperature dependence.
This independent educational reconstruction is not affiliated with any museum, journal, archive or historic institution.