1850
Rebuild Joule’s paddle wheel. Drop the weights, take imperfect thermometer readings, and recover the energy hidden in a degree of warmth.
Raw temperature gains transcribed from Table I, before the separate radiation correction. The shaded interval is ± one sample standard deviation calculated here from those original readings—not an error bar published by Joule.
Three independent numerical routes check the model without using the noisy thermometer estimate.
For total suspended mass m, drop height h, gravity g and n releases, the gravitational work is W = nmgh. The model sends a fraction η of this work into the stirred calorimeter. Its heat capacity is C = (mᵥ + mₑ)c with an equivalent water mass for the copper vessel and brass paddles. The ideal warming is ΔT = ηW/C.
With ambient coupling, C dT/dt = ηP − k(T − Tₐ). The display uses fixed-step RK4 and checks it against the exponential closed form for constant power. The scene is a mechanical illustration, not a computational fluid simulation.
Each observation is a quantised temperature reading plus independent zero-mean Gaussian instrument noise. A linear calibration drift is added over the 35-minute session. The experiment compares two readings, so a constant zero offset cancels, but drift and fluctuating noise do not. Ambient exchange changes the water temperature physically. These are plausible instrument mechanisms; their magnitudes are user-controlled illustrations, not fitted reconstructions of Joule’s individual error sources.
The inferred constant is E = ηW / [(mᵥ + mₑ) ΔTₒᵦₛ × 1000] joules per calorie, using one calorie per gram-degree of equivalent water. When the observed rise is zero or overwhelmed by uncertainty, the exhibit withholds a reliable result.
Joule's 1850 paper records two lead weights totalling 406,152 grains, 20 drops of roughly 63 inches, 93,229.7 grains of water, and 97,470.2 grains of total water-equivalent capacity. He reported a corrected mean work of 6,067.114 ft·lbf, a corrected rise of 0.563209 °F, and 773.640 ft·lbf per pound-degree before vacuum correction; his preferred published value was 772.692 ft·lbf per pound-degree. Those values should not be mistaken for exact input physics.
The original Table I contains 40 uncorrected friction readings. Their mean and sample deviation can be computed, but the spread is not a published historical confidence interval and includes effects of changing lab conditions. Modern water specific heat also varies slightly with temperature. The exhibit uses 4,184 J/(kg·K) for a transparent modern convention.
Primary source: J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions 140 (1850), pp. 61–82, especially Table I and Table IX. The historical text is available through the Philosophical Transactions Archive. The Science Museum Group collection documents Joule's surviving copper vessel and apparatus (object 1876-492). This simulation does not contact either source.
This is an independent educational reconstruction and is not affiliated with the Science Museum Group, Royal Society, or any historical estate. Not all pulleys, bearings or radiative corrections can be shown to scale.