MY SIMULATOR / EXPERIMENTAL ARCHIVETHERMODYNAMICS · 1850

HISTORICAL LABORATORY · SERIES I

Joule's Cellar: Measuring the Mechanical Value of Heat

Turn falling weight into warmth. Reconstruct the water experiment published in 1850.

APPARATUS / CUTAWAYREADY
Illustrative geometry · drag to pan
Water temperature · model—
Corrected work · model—
Descent count · model—
Room exchange · model—

Ready to wind the weights.

Measurement notebook

Record completed trials. Each reading includes seeded thermometer noise, quantisation and calibration.

Your mean · measured—No trials recorded
Published · 1850772.692ft·lbf / Btu (water, vacuum)
Modern · IT Btu—ft·lbf / Btu

TrialΔT observed (°F)Work used (J)Estimate (ft·lbf/Btu)Error vs modern

Numerical verification

Independent checks of the model, not a guarantee of experimental accuracy.

The science

Textbook: W = Mgh; Q = CΔT; C dT/dt = P − K(T − Tair). The thermal ODE uses a fixed 0.25 s step. Within each step the duty-cycled work is integrated exactly across descent boundaries. The room term is evaluated explicitly.

Published: combined weights 406,152 grains; effective water capacity 97,470.2 grains; 20 descents totalling 1,260.248 inches; 35 minutes; descent speed 2.42 in/s. Joule's corrected work was 6,067.114 ft·lbf, corrected rise 0.563209 °F. His vacuum correction produced 772.692 ft·lbf per historical water heat unit.

Textbook conversion uses 1 IT Btu = 1055.05585262 J and 1 ft·lbf = 1.3558179483314 J. The historical water unit is not identical to a defined IT Btu. Water heat capacity here is approximated by the IT calorie convention (4.1868 J/g/K).

Illustrative model: measured room heat exchange is approximated by Newton cooling calibrated to Joule's published 0.04654 fractional response per trial. Mechanical correction uses the ratio of published corrected work to nominal gravitational work. Rewind timing is evenly distributed, and water is well mixed; no fluid dynamics are solved.

Noise: Joule described resolving around 0.005 °F and agreement between instruments around 0.01 °F. We use a 0.005 °F quantiser, independent Gaussian reading noise (user-adjustable), and a fixed illustrative gain error of 0.2% per trial. This is a reconstruction, not a measured historical probability distribution. Historical uncertainty is a reconstructed repeatability estimate, not an original published interval.

Sources: J. P. Joule, On the Mechanical Equivalent of Heat, Philosophical Transactions 140 (1850), 61–82, Tables I and IX; Science Museum Group, mechanical equivalent of heat apparatus, object co2526; Royal Society commentary, doi:10.1098/rsta.2014.0348. Not affiliated with any museum or institution.

Made with 🤖 ChatGPT